Fig. 4. 

VA140/ 150KT   Timer Model. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
Timer Adjustment. 
 

The overrun time period is factory set to approximately 15 minutes. The overrun time period may be adjusted at 
installation from 5-30 minutes, by altering the adjuster on the Fan PCB. 

 

Before adjusting the timer, switch off the Mains Supply. 

 

1.  Remove the Indoor Grille [A]. Loosen the screw (top middle) of the Grille, to release front grille gently lever the 

Grille downwards away from the Inner Cover [B]. 

2.  Remove Inner Cover [B]. Loosen the screw (bottom middle) and release the inner grille gently from the Base 

Housing [D]. 

3.  To REDUCE the operating time, turn the Timer Adjuster ANTI-CLOCKWISE. 
4.  To INCREASE the operating time, turn the Timer Adjuster CLOCKWISE. 
5.  Replace the Inner Cover and Indoor Grille. 
6.  Reconnect the mains supply. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

~ N

E

Fan

L

LS

N

Timer Adjuster.

Summary of Contents for VA140/150KP

Page 1: ...140120C VA140 150KT 140220C VA140 150KHP 140320C VA140 150KHT 140420C VA140 150 RANGE Axial Kitchen Fans Installation and wiring Instructions 220 240V 50Hz READ IN CONJUNCTION WITH ILLUSTRATIONS PLEAS...

Page 2: ...m C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended tha...

Page 3: ...tly from the Base Housing D 6 Remove the Cable Grommet C pierce cut a hole in the Grommet to suit the cable size maintaining the integrity of the seal and replace the grommet in the Base Housing to su...

Page 4: ...sure all terminal connections and cable clamps are securely fastened 3 The cable entry must be made using the cable grommet 4 Ensure the impeller rotates and is free from obstructions Fig 3 VA140 150K...

Page 5: ...Indoor Grille A Loosen the screw top middle of the Grille to release front grille gently lever the Grille downwards away from the Inner Cover B 2 Remove Inner Cover B Loosen the screw bottom middle an...

Page 6: ...ver B 2 Remove Inner Cover B Loosen the screw bottom middle and release the inner grille gently from the Base Housing D 3 To LOWER the Set Point turn the adjuster ANTI CLOCKWISE This makes the fan mor...

Page 7: ...akes the fan more sensitive to RH i e the fan will come on at a lower RH or will reduce the overrun time 4 To RAISE the Set Point operating time turn the adjuster CLOCKWISE This makes the fan less sen...

Page 8: ...t will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connec...

Reviews: