Vent-Axia VA100 Series Installation And Wiring Instructions Download Page 7

 

 

 

 

 
 

PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)               No 1254/2014) 

 
 

 

Name:  

Vent-Axia 

Vent-Axia 

Vent-Axia 

Vent-Axia 

Vent-Axia 

Vent-Axia 

Vent-Axia 

Model ID (Stock Ref.) : 

VA100LP - 

251110 

VA100LT - 

251210 

VA100XP - 

251310 

VA100XT - 

251410 

VA100LHP - 

251610 

VA100XHP - 

251710 

VA100XHT - 

251510 

SEC Class 

SEC Value ('Average') 

13.97 

15.72 

13.97 

15.72 

26.23 

26.23 

26.23 

SEC Value ('Warm') 

6.32 

7.11 

6.32 

7.11 

11.86 

11.86 

11.86 

SEC Value ('Cold') 

27.32 

30.75 

27.32 

30.75 

51.31 

51.31 

51.31 

Label Required? (Yes/No=Out of scope) 

No 

No 

No 

No 

No 

No 

No 

Declared as: RVU or NRVU/UVU or BVU 

RVU-UVU 

RVU-UVU 

RVU-UVU 

RVU-UVU 

RVU-UVU 

RVU-UVU 

RVU-UVU 

Speed Drive 

Multi-Speed 

Multi-Speed 

Multi-Speed 

Multi-Speed 

Multi-Speed 

Multi-Speed 

Multi-Speed 

Type HRS (Recuperative, Regenerative, 
None) 

None 

None 

None 

None 

None 

None 

None 

Thermal Eff: [ (%), NA(if none)] 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

Max. Flow Rate (m3/h) 

108.00 

108.00 

108.00 

108.00 

108.00 

108.00 

108.00 

Max. Power Input (W): (@Max.Flow Rate) 

20.00 

20.00 

20.00 

20.00 

20.00 

20.00 

20.00 

LWA: Sound Power Level (dB) 

53.52 

53.52 

53.52 

53.52 

53.52 

53.52 

53.52 

Ref. Flow Rate (m3/s) 

0.02 

0.02 

0.02 

0.02 

0.02 

0.02 

0.02 

Ref. Pressure Diff. (Pa) 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

SPI [W/(m3/h)] 

0.26 

0.26 

0.26 

0.26 

0.26 

0.26 

0.26 

Control Factor & Control Typology: (CTRL/ 
Typology) 

  

  

  

  

  

  

  

Control Factor; CTRL 

1.00 

0.95 

1.00 

0.95 

0.65 

0.65 

0.65 

Control Typology 

Manual 
Control 

Clock Control 

Manual 
Control 

Clock Control 

Local 

Demand 

Control 

Local 

Demand 

Control 

Local 

Demand 

Control 

Declared: -Max Internal & External Leakage 
Rates(%) for BVUs or carry over (for 
regenerative heat exchangers only),                                                                                          
-&Ext. Leakage Rates (%) for Ducted UVUs; 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

Mixing Rate of Non-Ducted BVUs not 
intended to be equipped with one duct 
connection on either supply or extract air 
side; 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

Position and description of visual filter 
warning for RVUs intended for use with 
filters, including text pointing out the 
importance of regular filter changes for 
performance and energy efficiency of the 
unit 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

For UVUs (Instructions Install Regulated 
Supply/Extract Grilles Façade) 

In F&W 

In F&W 

In F&W 

In F&W 

In F&W 

In F&W 

In F&W 

Internet Address (for Disassembly 
Instructions) 

www.vent-

axia.com 

www.vent-

axia.com 

www.vent-

axia.com 

www.vent-

axia.com 

www.vent-

axia.com 

www.vent-

axia.com 

www.vent-

axia.com 

Sensitivity p. Var20/-20 Pa: (for 
Non-Ducted Vus) 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

Air Tightness-ID/OD-(m3/h) (for Non-Ducted 
Vus) 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

N/A 

Annual Electricity Consumption: AEC 
(kWh/a) 

3.65 

3.38 

3.65 

3.38 

1.91 

1.91 

1.91 

Annual Heating Saved: AHS (kWh/a) 

  

  

  

  

  

  

  

AHS: Average 

13.97 

15.72 

13.97 

15.72 

26.23 

26.23 

26.23 

AHS: Warm 

6.32 

7.11 

6.32 

7.11 

11.86 

11.86 

11.86 

AHS: Cold 

27.32 

30.75 

27.32 

30.75 

51.31 

51.31 

51.31 

 

 

Summary of Contents for VA100 Series

Page 1: ...N VA100LP 25 11 10B VA100LT 25 12 10B VA100XP 25 13 10C VA100XT 25 14 10C VA100LHP 25 16 10E VA100XHP 25 17 10F VA100XHT 25 15 10C PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SA...

Page 2: ...at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The fan should only be used in conjunction with the appropriate Vent Axia products E It is reco...

Page 3: ...closed duct system or protected by an exterior air grille 1 Cut a 105mm diameter hole in the fixing surface 2 Remove the grille by loosening the screw at the bottom of the grille 3 Mark the screw cent...

Page 4: ...he side cable entry option is used ensure the supplied grommet is used and maintains a good seal to prevent water ingress The VA100 is suitable for connection to 220 240V 1 50Hz supply It is class II...

Page 5: ...sensitivity to the desired position The controller is already factory set to switch on at about 70 R H SHUTTER OPERATION The shutter mechanism in all VA100 X model fans will open approximately one min...

Page 6: ...SWITCHED FUSED SPUR 1A Fig 1 Fig 2 VA100L Fig 3 VA100X VA100LH VA100XH Fig 4 VA100XT VA100LT VA100XHT VA100LH VA100XH LS CAN BE USED AS OVERRIDE N L 1 PHASE SUPPLY 220 240V 50Hz FUSE SWITCHED FUSED SP...

Page 7: ...CTRL Typology Control Factor CTRL 1 00 0 95 1 00 0 95 0 65 0 65 0 65 Control Typology Manual Control Clock Control Manual Control Clock Control Local Demand Control Local Demand Control Local Demand C...

Page 8: ...Crawley West Sussex RH10 9YX Tel 01293 526062 Fax 01293 551188 UK NATIONAL CALL CENTRE Newton Road Crawley West Sussex RH10 9JA SALES ENQUIRIES Tel 0844 8560590 Fax 01293 565169 TECHNICAL SUPPORT Tel...

Reviews: