G. FAULT FINDING.
The Lo-Carbon PoziDry has built in fault detection software to ensure continual safe functioning.
If one of the following faults appears on the LCD display please contact Technical Support on 0844 8560594.
F1 = Open circuit thermistor i.e. not connected.
F2 = Short circuit thermistor i.e. wires, PCB or thermistor shorted.
The above codes are mutually exclusive so cannot occur at the same time.
F3 = Motor Tachometer signal failure or fan not rotating.
F4 = Motor AND open circuit thermistor failures.
F5 = Motor AND short circuit thermistor failures.
PRODUCT FICHE
For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014)
Name:
Vent-Axia
Vent-Axia
Model ID (Stock Ref.) :
Lo-Carbon PoziDry
Compact - 444076
Lo-Carbon PoziDry
Compact - 444767
SEC Class
E
E
SEC Value ('Average')
28.30
28.30
SEC Value ('Warm')
12.80
12.80
SEC Value ('Cold')
55.36
55.36
Label Required? (Yes/No=Out of scope)
Yes
Yes
Declared as: RVU or NRVU/UVU or BVU
RVU-UVU
RVU-UVU
Speed Drive
Multi-Speed
Multi-Speed
Type HRS (Recuperative, Regenerative, None)
None
None
Thermal Eff: [ (%), NA(if none)]
N/A
N/A
Max. Flow Rate (m3/h)
122.40
122.40
Max. Power Input (W): (@Max.Flow Rate)
49.80
49.80
LWA: Sound Power Level (dB)
N/A - (Ducted)
N/A - (Ducted)
Ref. Flow Rate (m3/s)
0.02
0.02
Ref. Pressure Diff. (Pa)
TBC
TBC
SPI [W/(m3/h)]
0.58
0.58
Control Factor & Control Typology: (CTRL/ Typology)
Control Factor; CTRL
0.65
0.65
Control Typology
Local Demand
Control
Local Demand
Control
Declared: -Max Internal & External Leakage Rates(%) for BVUs or
carry over (for regenerative heat exchangers only),
-&Ext. Leakage Rates (%) for Ducted UVUs;
TBC
TBC
Mixing Rate of Non-Ducted BVUs not intended to be equipped
with one duct connection on either supply or extract air side;
N/A
N/A
Filter Warning (RVU)
No
No
For UVUs (Instructions Install Regulated Supply/Extract Grilles
Façade)
In F&W
In F&W
Internet Address (for Disassembly Instructions)
www.vent-axia.com
www.vent-axia.com
Sensitivity p. Var20/-20 Pa: (for Non-Ducted Vus)
TBC
TBC
Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus)
TBC
TBC
Annual Electricity Consumption: AEC (kWh/a)
9.54
9.54
Annual Heating Saved: AHS (kWh/a)
AHS: Average
28.30
28.30
AHS: Warm
12.80
12.80
AHS: Cold
55.36
55.36