PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Name:

  

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

Lo

Carbon

 

Centra

 

T

 

‐ 

442954

 

Lo

Carbon

 

Centra

 

TP

 ‐ 

447127

 

Lo

Carbon

 

Centra

 

HT

 ‐ 

442955

  

Lo

Carbon

 

Centra

 

HTP

 ‐ 

443045

 

SEC

 

Class

 

E

 

E

 

C

 

C

 

SEC

 

Value

 

('Average')

 

15.72

 

15.72

 

26.23

 

26.23

 

SEC

 

Value

 

('Warm')

 

7.11

 

7.11

 

11.86

 

11.86

 

SEC

 

Value

 

('Cold')

 

30.75

 

30.75

 

51.31

 

51.31

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

No

 

No

 

No

 

No

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

Speed

 

Drive

 

2

Speed

 

2

Speed

 

2

Speed

 

2

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

 

None

 

None

 

None

 

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

 

N/A

 

N/A

 

N/A

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

54.00

 

54.00

 

54.00

 

54.00

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

2.40

 

2.40

 

2.40

 

2.40

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

33.02

 

33.02

 

33.02

 

33.02

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.01

 

0.01

 

0.01

 

0.01

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

N/A

 

N/A

 

N/A

 

N/A

 

SPI

 

[W/(m3/h)]

 

0.06

 

0.06

 

0.06

 

0.06

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

  

  

  

Control

 

Factor;

 

CTRL

 

0.95

 

0.95

 

0.65

 

0.65

 

Control

 

Typology

 

Clock

 

Control

 

Clock

 

Control

 

Local

 

Demand

 

Control

 

Local

 

Demand

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                    

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

N/A

 

N/A

 

N/A

 

N/A

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

N/A

 

N/A

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

0.82

 

0.82

 

0.52

 

0.52

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

  

  

  

AHS:

 

Average

 

15.72

 

15.72

 

26.23

 

26.23

 

AHS:

 

Warm

 

7.11

 

7.11

 

11.86

 

11.86

 

AHS:

 

Cold

 

30.75

 

30.75

 

51.31

 

51.31

 

Summary of Contents for Lo-Carbon Centra Series

Page 1: ...B Lo Carbon Centra T 442955B Lo Carbon Centra HT 447127B Lo Carbon Centra TP 443045B Lo Carbon Centra HTP PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo C...

Page 2: ...iance ensure that the air replacement is adequate for both the fan and the fuel burning appliance G The Fan should not be used where it is liable to be subject to direct water spray for prolonged peri...

Page 3: ...aces 2 Loosen the screw in the bottom of the grille and remove the front grille Mark the screw centres through the holes in the fan back plate Drill plug and screw into position 3 Fix exterior grille...

Page 4: ...lity via remote switch T TP HT HTP Fig 1 Continuous trickle with no remote boost facility T TP 2 Pull grille slightly away from bottom edge 3 Push grille upwards until clear from the fan chassis 1 Loo...

Page 5: ...connection is switched off With jumper JP2 in place there will be no overrun timer when the LS connection is switched off the fan will leave boost Pullcord TP HTP The integral pullcord activates the...

Page 6: ...t face with a damp cloth until clean The fan has sealed for life bearings which do not require lubrication DATA LOGGER The fan records the number of days it has been running for In order to use this f...

Page 7: ...l Factor CTRL 0 95 0 95 0 65 0 65 Control Typology Clock Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regener...

Page 8: ...not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Ve...