Vent-Axia Centrif Duo DP 25 63 20D Installation And Wiring Instructions Download Page 16

16 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The

 

 

Guarantee 

 

Applicable only to products installed and used in the United Kingdom.  For details of guarantee outside the United Kingdom contact 

your local supplier. 

 

Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship.  In the event of any 

part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the 

product:- 

 

 

Has been installed and used in accordance with the instructions given with each unit. 

 

Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the 
product rating label attached to the unit). 

 

Has not been subjected to misuse, neglect or damage. 

 

Has not been modified or repaired by any person not authorised by the company. 

 

IF CLAIMING UNDER TERMS OF GUARANTEE 

Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit.  

Please ensure that it is adequately packed and accompanied by a letter clearly marked “Guarantee Claim” stating the nature of the 

fault and providing evidence of date and source of purchase. 

 

The guarantee is offered to you as an extra benefit, and does not effect your legal rights 

Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188 

UK NATIONAL CALL CENTRE

,  Newton Road, Crawley, West Sussex, RH10 9JA

 

SALES ENQUIRIES:    

 

Tel: 0844 8560590  

Fax: 01293 565169

  

TECHNICAL SUPPORT: 

 

Tel: 0844 8560594  

Fax: 01293 539209 

Web:-www.vent-axia.com   Email:- 

[email protected]

 

As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice. 

 
446141E        1116 

Summary of Contents for Centrif Duo DP 25 63 20D

Page 1: ...f N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Plus P 43 16 13B Centrif Duo Plus T 43 16 14B Centrif Duo Plus DP 43 16 15B Centrif D...

Page 2: ...separately Washable filter available separately for Centrif Duo Plus Pullcord Trickle speed LS connection to boost from a remote switch from off or trickle speed Two boost speed options available sel...

Page 3: ...be used where it is liable to be subject to direct water spray for prolonged periods of time I Where ducted fans are used to handle moisture laden air a condensation trap should be fitted Horizontal...

Page 4: ...at there is sufficient space for the product to be installed and that the Filter fig 3 can be removed for maintenance 3 Insert the wall sleeve with the larger diameter sleeve on the room side and ceme...

Page 5: ...that all covers are on correctly to ensure the optimum performance and water ingress protection of the fan 14 Switch the mains power supply on and check the fan is operating correctly B SETUP WARNING...

Page 6: ...f the two on the control PCB fig 4 7 i To REDUCE the operating time turn the timer adjuster ANTI CLOCKWISE ii To INCREASE the operating time turn the timer adjuster CLOCKWISE 4 RELATIVE HUMIDITY ADJUS...

Page 7: ...ash it and the front cover assembly in warm soapy water Dry them before replacing 3 Wipe the inlets and front face with a damp not dripping wet cloth until clean 4 Replace the filter 5 Turn the power...

Page 8: ...ave a metal mesh filter clipped on to the rear of the cover It can be removed easily and washed too Fig 4 Terminal Block Cover Cable Clamp Terminal Block PCB Cover and Screws Humidity Adjustment HTP m...

Page 9: ...9 Fig 5 Frame from optional Flush Mount Kit 4 screws Back Box Fig 6 Panel Clip Screw 4 off Panel Clip 4 off Chassis...

Page 10: ...ARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE TO ACCESS THE SPEED CONTROLS PCB REMOVE THE TWO SCREWS HOLDING THE PCB COVER IN...

Page 11: ...ds PIR sensors or humidistats can be fitted in line with the mains live connection L in order to turn the fan or off N L Ls 1 Phase Supply 220 240V 50 Hz 3A Fuse Pull Cord Lamp 3 Pole Isolator Switch...

Page 12: ...l Factor CTRL 0 65 0 65 0 65 0 65 Control Typology Local Demand Control Timer control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for...

Page 13: ...27 Control Factor Control Typology CTRL Typology Control Factor CTRL 0 65 0 65 0 65 0 65 Control Typology Local Demand Control Timer control Timer control Local Demand Control Declared Max Internal Ex...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...fied or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre...

Reviews: