Vent-Axia Centrif Duo DP 25 63 20D Installation And Wiring Instructions Download Page 12

12 

PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)                           

No 1254/2014) 

Name:

  

Vent

Axia

  

Vent

Axia

  

Vent

Axia

  

Vent

Axia

  

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

Centrif

 

Duo

 

P

 ‐ 

256120

 

Centrif

 

Duo

 

T

 ‐ 

256220

 

Centrif

 

Duo

 

DP

 

‐ 

256320

 

Centrif

 

Duo

 

HTP

 ‐ 

256420

 

SEC

 

Class

 

D

 

D

 

D

 

D

 

SEC

 

Value

 

('Average')

 

26.23

 

26.23

 

26.23

 

26.23

 

SEC

 

Value

 

('Warm')

 

11.86

 

11.86

 

11.86

 

11.86

 

SEC

 

Value

 

('Cold')

 

51.31

 

51.31

 

51.31

 

51.31

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

Yes

 

Yes

 

Yes

 

Yes

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

Speed

 

Drive

 

2

Speed

 

2

Speed

 

2

Speed

 

2

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

 

None

 

None

 

None

 

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

 

N/A

 

N/A

 

N/A

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

219.60

 

219.60

 

219.60

 

219.60

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

60.00

 

60.00

 

60.00

 

60.00

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

60.42

 

60.42

 

60.42

 

60.42

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.04

 

0.04

 

0.04

 

0.04

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

135.00

 

135.00

 

135.00

 

135.00

 

SPI

 

[W/(m3/h)]

 

0.27

 

0.27

 

0.27

 

0.27

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

  

  

  

Control

 

Factor;

 

CTRL

 

0.65

 

0.65

 

0.65

 

0.65

 

Control

 

Typology

 

Local

 

Demand

 

Control

 

Timer

 

control

 

Local

 

Demand

 

Control

 

Local

 

Demand

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                         

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

N/A

 

N/A

 

N/A

 

N/A

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

N/A

 

N/A

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

2.19

 

2.19

 

2.19

 

2.19

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

  

  

  

AHS:

 

Average

 

26.23

 

26.23

 

26.23

 

26.23

 

AHS:

 

Warm

 

11.86

 

11.86

 

11.86

 

11.86

 

AHS:

 

Cold

 

51.31

 

51.31

 

51.31

 

51.31

 

 

Summary of Contents for Centrif Duo DP 25 63 20D

Page 1: ...f N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Plus P 43 16 13B Centrif Duo Plus T 43 16 14B Centrif Duo Plus DP 43 16 15B Centrif D...

Page 2: ...separately Washable filter available separately for Centrif Duo Plus Pullcord Trickle speed LS connection to boost from a remote switch from off or trickle speed Two boost speed options available sel...

Page 3: ...be used where it is liable to be subject to direct water spray for prolonged periods of time I Where ducted fans are used to handle moisture laden air a condensation trap should be fitted Horizontal...

Page 4: ...at there is sufficient space for the product to be installed and that the Filter fig 3 can be removed for maintenance 3 Insert the wall sleeve with the larger diameter sleeve on the room side and ceme...

Page 5: ...that all covers are on correctly to ensure the optimum performance and water ingress protection of the fan 14 Switch the mains power supply on and check the fan is operating correctly B SETUP WARNING...

Page 6: ...f the two on the control PCB fig 4 7 i To REDUCE the operating time turn the timer adjuster ANTI CLOCKWISE ii To INCREASE the operating time turn the timer adjuster CLOCKWISE 4 RELATIVE HUMIDITY ADJUS...

Page 7: ...ash it and the front cover assembly in warm soapy water Dry them before replacing 3 Wipe the inlets and front face with a damp not dripping wet cloth until clean 4 Replace the filter 5 Turn the power...

Page 8: ...ave a metal mesh filter clipped on to the rear of the cover It can be removed easily and washed too Fig 4 Terminal Block Cover Cable Clamp Terminal Block PCB Cover and Screws Humidity Adjustment HTP m...

Page 9: ...9 Fig 5 Frame from optional Flush Mount Kit 4 screws Back Box Fig 6 Panel Clip Screw 4 off Panel Clip 4 off Chassis...

Page 10: ...ARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE TO ACCESS THE SPEED CONTROLS PCB REMOVE THE TWO SCREWS HOLDING THE PCB COVER IN...

Page 11: ...ds PIR sensors or humidistats can be fitted in line with the mains live connection L in order to turn the fan or off N L Ls 1 Phase Supply 220 240V 50 Hz 3A Fuse Pull Cord Lamp 3 Pole Isolator Switch...

Page 12: ...l Factor CTRL 0 65 0 65 0 65 0 65 Control Typology Local Demand Control Timer control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for...

Page 13: ...27 Control Factor Control Typology CTRL Typology Control Factor CTRL 0 65 0 65 0 65 0 65 Control Typology Local Demand Control Timer control Timer control Local Demand Control Declared Max Internal Ex...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...fied or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre...

Reviews: