L110

Model

B100 Single

Volts

Amps

RPM

CFM

[email protected]

Equivalent CFM

CFM

[email protected]

CFM

[email protected]

CFM

[email protected]

Minimum Round

Duct Size

Square

Inches

#

B200 Dual

115

115

1.7

3.4

1550

1550

300

600

450

900

286

572

270

540

240

480

6” (or equivalent)

8” (or equivalent)

28

50

Note: Add 2.5 amps for each warming light and 0.5 amp for each halogen light.
Because the Magic Lung   uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung   blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently 
than other than other filtration systems. When comparing the Magic Lung    with other blower units made by other manufacturers, use the “Equivalent CFM”.

*

TM

TM

TM

*
#

8) Install an appropriate 1/2" UL listed electrical wire clamp through each motor box electrical opening on top of the

hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection
diagrams (on previous page) for further details on electrical placement.

Method 1: Extend wiring to 30" above the countertop. Electrical connection(s) will occur after the hood is installed on

the wall.

Method 2: Extend wiring to the hood. Electrical connection(s) will occur before the hood is installed on the wall.

Installation Details Continued

9) If using a duct cover, carefully remove the knockouts from the top four corners of the hood. Remove the duct cover

from its packaging and remove the mounting screws from the base of the duct cover. Place the duct cover on the top
of the hood and secure it temporarily through the knockout openings using the mounting screws previously removed.
Lift the hood and duct cover assembly to the location on the wall where it will be installed.

Lightly mark the wall with a short, horizontal mark along the bottom edge of the hood. When finished, remove the hood
and duct cover assembly from the wall. Remove the duct cover that was previously installed on the hood and set both
items aside.

10) On the back side of the hood, measure the distance between the bottom edge of the hood and the top edge of the wood

mounting strip. Measure this distance above the horizontal mark made in Step 9 and lightly mark the wall with a level,
horizontal line. Measure where the center (left to right) of the hood will be and mark the upper, horizontal line on the
wall with a short, vertical centerline.

11) Remove the screws inside the top of the back of the hood that retain the wood strip that is recessed in the mounting

channel. Note: Some retaining screws may be located behind the blower(s). Remove the wood mounting strip from the
back of the hood and place the top edge of the strip on the upper, level, horizontal line on the wall. Referencing the
vertical centerline from Step 10, place the mounting strip on the wall so it is centered (left to right) in the space where
the hood will be located. Drill pilot holes in the strip to prevent splitting. Using proper hardware, attach the mounting
strip to at least two wall studs.

12) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 13. Note: Wall

studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut duct
access hole(s) in the wall prior to installing the hood.

Method 1: Hold the hood on the mounting strip by aligning the channel at the top of the back of the hood over the

wood mounting strip on the wall. Place the appropriate elbow(s) on top of the hood in line with the hood
exhaust collar(s). On the wall, trace around the elbow(s). Remove the hood and elbow(s) from the wall. Cut
around the outside of the traced line(s), avoiding wall studs. Install the duct from the outside of the home to
the opening in the wall. Use duct tape to seal joints.

Method 2: Using the applicable venting accessories and the connection diagrams (previous page) as a guide, install

the duct(s) from the outside of the home to the wall over the exhaust outlet(s) on the hood. The end of the
duct(s) should extend 1" past the wall.

13) Hang the hood on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting

strip on the wall. While holding the hood in place, mark locations on the mounting strip through the two mounting
holes in the channel at the top of the hood. Some mounting holes may be located behind the blower(s). Remove the
hood and drill 3/32" pilot holes at the center of the marks in the wood strip to prevent splitting.

Summary of Contents for 300 CFM B100

Page 1: ...service disconnecting means to prevent power from being switched on accidentally during installation B When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden u...

Page 2: ...ormance Only use smooth galvanized metal duct Observe local codes regarding special duct requirements and placement of duct against combustibles Make the duct run as short and as straight as possible...

Page 3: ...all the duct s from the outside of the home down to the location of the exhaust outlet s on the top of the hood allowing room for the transition if applicable If a transition is used install duct down...

Page 4: ...s Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches B one on each side of the housing The housing s should be pulled forwar...

Page 5: ...ng strip Measure this distance above the horizontal mark made in Step 9 and lightly mark the wall with a level horizontal line Measure where the center left to right of the hood will be and mark the u...

Page 6: ...installing the screws previously removed from the strip in Step 11 into the pilot holes drilled in Step 13 Use duct tape to seal joints Insert the electrical wire from the service panel into the elec...

Page 7: ...10 RD MODEL DIM WALL LOUVER 11 2 FLANGE 13 13 VP555 12 RD MODEL DIM ADJUSTABLE ELBOW 6 7 8 ROUND VP513 6 VP514 7 VP515 8 MODEL DIM 11 16 11 10 3 1 4 6 VP550 6 3 1 4 x10 MODEL DIM VP561 8 6 x 8 1 2 MOD...

Reviews: