Read and Save These Instructions

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS

WALL MOUNT RANGE HOOD

Read All Instructions Thoroughly Before Beginning Installation

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction. Switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally during installation.

B. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

C. Ducted fans must always be vented to the outdoors.

D. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and local code authorities.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL

DUCTWORK

Summary of Contents for 300 CFM B100

Page 1: ...service disconnecting means to prevent power from being switched on accidentally during installation B When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden u...

Page 2: ...ormance Only use smooth galvanized metal duct Observe local codes regarding special duct requirements and placement of duct against combustibles Make the duct run as short and as straight as possible...

Page 3: ...all the duct s from the outside of the home down to the location of the exhaust outlet s on the top of the hood allowing room for the transition if applicable If a transition is used install duct down...

Page 4: ...s Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches B one on each side of the housing The housing s should be pulled forwar...

Page 5: ...ng strip Measure this distance above the horizontal mark made in Step 9 and lightly mark the wall with a level horizontal line Measure where the center left to right of the hood will be and mark the u...

Page 6: ...installing the screws previously removed from the strip in Step 11 into the pilot holes drilled in Step 13 Use duct tape to seal joints Insert the electrical wire from the service panel into the elec...

Page 7: ...10 RD MODEL DIM WALL LOUVER 11 2 FLANGE 13 13 VP555 12 RD MODEL DIM ADJUSTABLE ELBOW 6 7 8 ROUND VP513 6 VP514 7 VP515 8 MODEL DIM 11 16 11 10 3 1 4 6 VP550 6 3 1 4 x10 MODEL DIM VP561 8 6 x 8 1 2 MOD...

Reviews: