background image

Advanced Setup

NOTE:

 Each step # is located at

            the top right corner of the
            display for easy reference.

Press

MODE

Press

MODE

Press

MODE

Continued

Adjust the time 
of day clock.

Leave this setup 
step set to NO.

Select the day 
of the week.

3

Setup

2o

e

2

Setup

   M

I

Setup

Am

I2 00

:

Yes

No

MODE

FAN

MODE

Press the MODE button and
release.

Immediately press the MODE 
button again.  While holding 
the MODE button, press the 
FAN button.  When this 
screen appears

I

Setup

Am

12:00

:

                       DO NOT 
                       RELEASE THE 
                       BUTTONS.  
Continue holding the MODE 
and FAN buttons for an add-
itional seven seconds to 
enter Setup screens beyond 
step #2. 

Tip: To change hours quickly, press 
       and hold the FAN button, then press the UP or DOWN button.

Page 12

O

Summary of Contents for T1100RF

Page 1: ...7 Day Programmable 4 Settings Day Auto Changeover 5 minute Built In Compressor Protection Self Prompting Programming w Copy Full Electronic Display Either F or C Back Lit Display Keypad Lockout Large...

Page 2: ...se undesired operation C c F T1100RF FCC ID MUH T10013 CAUTION Follow Installation Instructions carefully DISCONNECT POWER TO THE HEATER AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLI...

Page 3: ...E 67 70 HEAT COOL AUTO o o Am 6 03 68 Su Front Panel Liquid Crystal Display with Thermoglow Up Down Buttons Mode Button Fan Button Transmission Indicator Blinking Green Communicating with the Receiver...

Page 4: ...es the system will automatically changeover between heat and cool modes as the temperature varies PROGRAM ON Indicates the time period program is enabled to run OFF Indicates heating and cooling are t...

Page 5: ...s in the setup mode Fan On icon Page 7 Indicates constant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or cool Locked icon Page 18 Indicat...

Page 6: ...te one or two stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section The thermostat is not prepr...

Page 7: ...nly The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room Cooling Only OFF indicates both heating and air conditioning systems are t...

Page 8: ...L MODE Pressing the UP or DOWN button in Heat or Cool mode will adjust only the heat or cool set temperature 76 COOL o Pm 12 00 70 M buttons Adjust the desired set temperature with the Selecting Your...

Page 9: ...OL o o Am 6 00 Morning M Use the Programming Worksheet on the back cover to help with this section Press the MODE button While holding MODE press the UP button for two seconds to enter time period pro...

Page 10: ...COOL o Pm 6 00 M Start Pm 6 00 Evening M Day 62 85 HEAT COOL o o Am 8 00 M Adjust the start time for Evening Adjust the start time for Day Adjust the cooling setpoint for Evening Adjust the heating se...

Page 11: ...78 HEAT COOL o o Night Night 82 COOL o Pm I0 00 M 62 82 HEAT COOL o o I0 00 M Unit 1 only Programming a Daily Schedule Adjust the start time for Night Adjust the heating setpoint for Evening Adjust t...

Page 12: ...n or each time this routine will repeat If No is selected as in previous steps flashing prompts for input will appear for the four time periods for the next day After programming for all seven days is...

Page 13: ...p M I Setup Am I2 00 Yes No MODE FAN MODE Press the MODE button and release Immediately press the MODE button again While holding the MODE button press the FAN button When this screen appears I Setup...

Page 14: ...tat is used each will need a different Unit ID number cy 8 Setup 6 5 Setup I 4 Setup o 6 Setup 2 7 HEAT COOL Setup 2 Note Available only on Unit ID 1 Adjust the deadband for the 1st stage 1 6 1 4 0 63...

Page 15: ...acklight operation ON Light continuously OFF Light for 8 seconds after a button press Adjust the program mable fan timer 0 60 minutes 0 00 off After programming is complete press the MODE and FAN butt...

Page 16: ...adaptor is used to power the thermostat Advanced Setup Advanced Setup Table Step Description Range Factory Default 1 2 3 4 5 6 7 8 9 10 11 Time of Day Day of the Week Zoning System House Code Unit ID...

Page 17: ...d Stage turn on 1st Stage turn on 2nd Stage turn on Heating Cooling TEMPERATURE DECREASE INCREASE non adj 2 non adj 2 About Advanced Features Operation Press button While holding the MODE button press...

Page 18: ...ngs follow the instructions below If for any reason you desire to return all the stored After all of the icons appear release the MODE and DOWN buttons Then press and hold the FAN button for 5 seconds...

Page 19: ...00 70 W MODE Press all three buttons in the order outlined above for keypad lockout BATTERY ELIMINATOR optional accessory t supply adaptor is used to power the thermostat and eliminate the need for r...

Page 20: ...ate with one hand while pulling on the top corner of the thermostat with your other hand Then turn the thermostat over to remove the batteries from the holder and replace with AA Lithium batteries You...

Page 21: ...OEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TI...

Page 22: ...py Thu Fri No Yes S U N D A Y Morning Day Evening Night Copy Sat Sun No Yes Copy Wed Thu W E N E S D D A Y T U R H S D A Y Morning Morning Day Day Evening Evening Night Night No Yes DAY PERIOD HEAT ST...

Reviews: