background image

venompower.com

0609

5

venompower.com

4. Press the CURRENT button to choose the appropriate working current 5A / 10A / 15A

    / 20A / 25A.
5. Press the MODE button to select the storage mode.
6. To select between LiPo (4.2V/cell) and LiHV (4.35V/cell) press the CURRENT and MODE 

buttons simultaneously for 4 seconds.

7. Press and hold the START/STOP button for 2 seconds to initiate the storage charge. An 

audible tone will sound and the LED channel indicator will glow RED upon initiation.

8. The storage charge process is complete when the LED channel indicator glows GREEN.

NOTE - Pressing the START/STOP button during an active storage will 

terminate the process.

NOTE - Charging a LiPo battery using the LiHV setting can cause permanent damage 

to the battery and even cause a fire.

2S/3S RADIO BATTERY CHARGE OPERATION

The 2S and 3S JST-XH charge ports located at the right side of the Pro Power HD are 

provided to charge a single LiPo (4.20V/cell) batteries with a capacity of 5000mAh or less. 

1. Connect a single 2S or 3S battery using the JST-XH balance connection from the battery.

2. Upon connection the charge process will start automatically and the LED indicator above 

the 2S & 3S charge ports will glows RED.

3. The charge process is complete when the LED indicator glows GREEN.

NOTE - Using the 2S and 3S charge ports simultaneously will cause permanent  

 

              damage to the charger.

LiPo AND LiHV MODE SELECTION

To select between the LiPo and LiHV settings press and hold the MODE and CURRENT 

buttons on the desired channel for 4 seconds. An audible alert will sound as the setting is 

changed and the LCD channel display will read either LiPo 4.20 or LiHV 4.35.

The Venom Pro Power HD is configurable to balance charge standard Lithium Polymer (LiPo) 

batteries as well as High Voltage Lithium Polymer (LiHV) batteries.

• LiPo mode is provided for lithium batteries having a nominal per cell voltage of 3.7V and 

a maximum per cell voltage of 4.2V
• LiHV mode is provided for lithium batteries having a nominal per cell voltage of 3.8V and 

a maximum per cell voltage of 4.35V

Summary of Contents for ProPowerHD Commercial Series

Page 1: ...OPERATING MANUAL LiPo LiHV CHARGER PROPOWERHD...

Page 2: ......

Page 3: ...agrees to bear all responsibilities of these risks and not hold Venom its distributors owners and employees and or retailers responsible for any accidents injury to persons or property damage If you...

Page 4: ..._ 4 7 Balance Charge Operation _____________________________________ 4 Storage Charge Operation ___________________________________ 4 5 2S 3S Radio Battery Charge Operation ___________________________...

Page 5: ...severely damaged catch fire and cause personal injury Refer to the battery label for the specifications of your battery pack or contact the manufacturer Battery packs when improperly charged or discha...

Page 6: ...ports for 2S and 3S radio batteries Auto recall of last charge settings Over voltage over current over temperature and reverse polarity protection 110 220VAC 1200W 600Wx2 80W 40Wx2 5A 10A 15A 20A 25A...

Page 7: ...OF UNIT FRONT RIGHT LEFT LCD Display LED Status Indicators Start Stop Buttons Charge Current Buttons Charge Storage Mode Buttons AC Power Input ON OFF Switch 2S 3S Radio Battery Charge Ports LED Indic...

Page 8: ...hold the START STOP button for 2 seconds to initiate the balance charge An audible tone will sound and the LED channel indicator will glow RED upon initiation 8 The balance charge process is complete...

Page 9: ...V cell batteries with a capacity of 5000mAh or less 1 Connect a single 2S or 3S battery using the JST XH balance connection from the battery 2 Upon connection the charge process will start automatical...

Page 10: ...part of the CC CV constant current constant voltage charging algorithm used for lithium batteries this value will decrease as the battery voltage rises 3 Elapsed Capacity The capacity added to or rem...

Page 11: ...ctions to the charger Reverse Polarity Battery polarity is reversed Check to verify the polarity of the battery main lead connection to the charger Cell Voltage High INT TEMP High Over Load Voltage ab...