Venmar VJ70330SS Instructions Manual Download Page 3

- 3 -

1. MEASURE THE INSTALLATION AND INSTALL DUCTWORK

The minimum hood distance above cooktop must not be less than 24” for best capture of
cooking impurities.

Decide where the ductwork will run between the hood and the outside.

A straight, short duct run will allow the hood to perform most efficiently.

Long duct runs, elbows and transitions will reduce the performance of the hood. Use as
few of them as possible. Larger ducting may be required for best performance with longer 
duct runs.

Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards
the hood location. Use metal foil duct tape to seal the joints between ductwork sections.

WARNING

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

!

WARNING

To reduce the risk of fire, use only metal ductwork.

6

ROUND DUCT

ROOF CAP

ROUND
ELBOW

24

 ABOVE 

COOKING 

S

URFACE

WALL CAP

HOOD

DECORATIVE

FLUE

HH0094A

2. PREPARE THE INSTALLATION

Make sure that the following items are included:

1 - Hood
1 - Hood Glass Panel
1 - Decorative Flue Assembly (lower and upper flues)
1 - Metal Air Outlet
1 - Hood Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Parts Bag containing:

7 - No. 8 x 1¼” Flat Head Screws
9 - Drywall Anchors
2 - No. 8 x 1¼” Screws
2 - Washers
6 - No. 8 x 5/16” Screws
4 - Hood Glass Panel Special Flat Head Screws
4 - Hood Glass Panel Rubber Spacers

1 - Aluminum Grease Filter
1 - Installation Manual

HR0022

UPPER 
DECORATIVE FLUE

HOOD 

MOUNTING BRACKET

UPPER FLUE 
MOUNTING BRACKET

LOWER 
DECORATIVE FLUE

METAL

AIR OUTLET

!

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.

Summary of Contents for VJ70330SS

Page 1: ... LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 10 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional information visit www venmar ca INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...when cooking at high heat or when cooking flaming foods i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE TH...

Page 3: ...t it is recommended to wear safety glasses and gloves WARNING To reduce the risk of fire use only metal ductwork 6 ROUND DUCT ROOF CAP ROUND ELBOW 24 ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0094A 2 PREPARE THE INSTALLATION Make sure that the following items are included 1 Hood 1 Hood Glass Panel 1 Decorative Flue Assembly lower and upper flues 1 Metal Air Outlet 1 Hood Mounting Brack...

Page 4: ... cord exits from the hood see illustration at right Make sure this does not interfere with a mouting bracket fastening area or with the decorative flue where the flue touches the wall 3 WIRING INSTALLATION WARNING Electrical wiring must be done by qualified person s in accordance with all applicable codes and standards This range hood must be properly grounded Turn off electrical power at service ...

Page 5: ... flue bracket point down Use the upper flue mounting bracket as a template to mark the position of its screws Remove the mounting bracket Drill both screw holes using a 5 16 drill bit Insert the included drywall anchors into the drilled holes one per hole Secure the upper flue bracket to the wall using 2 no 8 x 1 flat head mounting screws Make sure that the bracket is thight against the wall C L H...

Page 6: ...o the top of the hood Remove all protective plastic film on the hood 2 Remove protective plastic film on the lower flue and install it over the hood 3 Insert each glass special flat head screw into their rubber spacer 6 INSTALL THE HOOD 6 WARNING Be careful when installing the decorative flue and hood they may have sharp edges HJ0010 HO0101 HO0102 ...

Page 7: ...lm on the upper flue to free its both side slots and slide it inside the lower flue 6 Align the hood and center it above the hood mounting bracket previously installed in step 5 Gently lower the hood until it is hung to the hood mounting bracket Using 2 no 8 x 1 flat head screws secure the lower flue bracket shaded part in the illustration at right to the wall CAUTION Do not overtight the screws w...

Page 8: ...e mounting bracket using 2 no 8 x 5 16 mounting screws 9 Remove the protective plastic film covering the upper flue 10 Remove grease filter in order to acces hood inner mounting holes First access grease filter by opening the hood front panel A Then remove the grease filter by pressing down on its metal latch tab and tilt filter downward B Set aside grease filter 6 INSTALL THE HOOD CONT D HJ0011 6...

Page 9: ...OOD MOUNTING HOLES 12 Restore electrical power at service panel HD0252 8 LIGHT BULBS This range hood requires two UL approved halogen bulbs JC type 12 V 20 W To replace bulbs 1 Gently push the rim upward and rotate to disengage the light bulb cover 2 Replace with JC type 12V 20 W Max G 4 base halogen bulb 3 Reinstall the light bulb cover by pushing the rim upward and rotating the light bulb cover ...

Page 10: ...ag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don ts Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow...

Page 11: ...screws 4 Rubber spacer 1 HL0108 Not illustrated 3 1 2 4 5 6 7 8 REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good working condition you must use Venmar Ventilation Inc genuine replacement parts only Venmar Ventilation Inc genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards...

Page 12: ...rvice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation Inc cannot be charged for them The duration of any implied warranty is limited to the 1 year period as speci...

Reviews: