Venmar VJ70330SS Instructions Manual Download Page 12

- 12 -

WARRANTY

VENMAR JAZZ RANGE HOOD

1-YEAR LIMITED WARRANTY

Venmar Ventilation Inc. warrants to the original consumer purchaser of its products, that such products will be free from defects in 
materials or workmanship for a period of one (1) year from date of original purchase. This warranty includes in-home service. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE. VENMAR VENTILATION INC. WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL 
PURCHASE PRICE OF A 

VENMAR JAZZ RANGE HOOD

, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.

During this one-year period, Venmar Ventilation Inc. will, at its option, repair or replace, without charge, any product or part which is found to be 
defective under normal use and service. 

THIS WARRANTY DOES NOT EXTEND TO BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS

AND OTHER ACCESSORIES FOR DUCTING

. This warranty does not cover a) normal maintenance and service b) any products or parts which have

been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation Inc., or c) a faulty installation
or installation contrary to recommended installation instructions.

Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation Inc. Where applicable, in-home service will be
made available only in areas where a contracted service provider offers service. If in-home service is not available, the product will be repaired or
replaced, at Venmar Ventilation Inc.’s discretion, by the nearest authorized service provider. The unit removal and reinstallation works are under the
customer responsibility, and Venmar Ventilation Inc. cannot be charged for them.

The duration of any implied warranty is limited to the 1-year period as specified for the express warranty. Some provinces do not allow limitation on
how long an implied warranty lasts, so the above limitation may not apply to you. VENMAR VENTILATION INC. OBLIGATION TO REPAIR OR
REPLACE AT VENMAR VENTILATION INC. OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.
VENMAR VENTILATION INC. SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN
CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF 
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. 

This warranty gives you specific legal rights and you may also have other rights, which vary from one province to another. This warranty supersedes
all prior warranties. To contact Venmar Ventilation Inc. Warranty Service call 1-800-567-3855 (in Canada). In order to qualify for a warranty claim, the
owner of a Venmar Jazz range hood must have the model and serial number along with a proof of the original purchase date. At the time of 
requesting service, describe the nature of any defect in the product or part.

Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville, Quebec CANADA  J2C 7W9

Tel.: 1-800-567-3855    Fax: 819-475-2660

www.venmar.ca

Summary of Contents for VJ70330SS

Page 1: ... LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 10 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional information visit www venmar ca INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...when cooking at high heat or when cooking flaming foods i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE TH...

Page 3: ...t it is recommended to wear safety glasses and gloves WARNING To reduce the risk of fire use only metal ductwork 6 ROUND DUCT ROOF CAP ROUND ELBOW 24 ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0094A 2 PREPARE THE INSTALLATION Make sure that the following items are included 1 Hood 1 Hood Glass Panel 1 Decorative Flue Assembly lower and upper flues 1 Metal Air Outlet 1 Hood Mounting Brack...

Page 4: ... cord exits from the hood see illustration at right Make sure this does not interfere with a mouting bracket fastening area or with the decorative flue where the flue touches the wall 3 WIRING INSTALLATION WARNING Electrical wiring must be done by qualified person s in accordance with all applicable codes and standards This range hood must be properly grounded Turn off electrical power at service ...

Page 5: ... flue bracket point down Use the upper flue mounting bracket as a template to mark the position of its screws Remove the mounting bracket Drill both screw holes using a 5 16 drill bit Insert the included drywall anchors into the drilled holes one per hole Secure the upper flue bracket to the wall using 2 no 8 x 1 flat head mounting screws Make sure that the bracket is thight against the wall C L H...

Page 6: ...o the top of the hood Remove all protective plastic film on the hood 2 Remove protective plastic film on the lower flue and install it over the hood 3 Insert each glass special flat head screw into their rubber spacer 6 INSTALL THE HOOD 6 WARNING Be careful when installing the decorative flue and hood they may have sharp edges HJ0010 HO0101 HO0102 ...

Page 7: ...lm on the upper flue to free its both side slots and slide it inside the lower flue 6 Align the hood and center it above the hood mounting bracket previously installed in step 5 Gently lower the hood until it is hung to the hood mounting bracket Using 2 no 8 x 1 flat head screws secure the lower flue bracket shaded part in the illustration at right to the wall CAUTION Do not overtight the screws w...

Page 8: ...e mounting bracket using 2 no 8 x 5 16 mounting screws 9 Remove the protective plastic film covering the upper flue 10 Remove grease filter in order to acces hood inner mounting holes First access grease filter by opening the hood front panel A Then remove the grease filter by pressing down on its metal latch tab and tilt filter downward B Set aside grease filter 6 INSTALL THE HOOD CONT D HJ0011 6...

Page 9: ...OOD MOUNTING HOLES 12 Restore electrical power at service panel HD0252 8 LIGHT BULBS This range hood requires two UL approved halogen bulbs JC type 12 V 20 W To replace bulbs 1 Gently push the rim upward and rotate to disengage the light bulb cover 2 Replace with JC type 12V 20 W Max G 4 base halogen bulb 3 Reinstall the light bulb cover by pushing the rim upward and rotating the light bulb cover ...

Page 10: ...ag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don ts Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow...

Page 11: ...screws 4 Rubber spacer 1 HL0108 Not illustrated 3 1 2 4 5 6 7 8 REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good working condition you must use Venmar Ventilation Inc genuine replacement parts only Venmar Ventilation Inc genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards...

Page 12: ...rvice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation Inc cannot be charged for them The duration of any implied warranty is limited to the 1 year period as speci...

Reviews: