Remove the knockouts for the chosen opening (vertical (
A
) or horizontal (
B
)) at the
back or on top of the hood and for electric connection.
NOTE: For the best ventilation performance, use a transition 3-1/4’’ x 10’’ to 6’’ (8.25 x 25.4
to 15.24 cm), if round duct is used. The wall duct must be well prepared to
receive the adapter. Before performing the installation, make sure the adapter
fits easily in the duct. If this hood replaces another hood, please note that location
of the air exhaust can vary from one manufacturer to another.
- 5 -
Remove the filters. Remove the screw located at the bottom of the hood and
remove the cover (
A
) and the adapter/damper assembly (
B
) from the inside of hood.
1
2
3
HO0010
A
B
4. CHOOSE THE OPENING
HD0038
HD0039
A
B
5. INSTALL THE ADAPTER
Using (2) 1/2’’ screws, secure the adapter to the top or back of the hood. Tape the
adapter to the hood using duct tape to seal it.
HD0005
HD0006