background image

4. INSTALL HOOD MOUNTING BRACKET

Once wall surface is finished, carefully trace a center line over installation 
location, then trace a level line at 43” distance from cooktop. Center and level the
hood mounting bracket, secure it to wall framing with 3 no. 8 x 1¼” flat head
mounting screws. 

- 5 -

Make sure power is switched off at service panel before starting installation.

When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.

5. INSTALL UPPER FLUE MOUNTING BRACKET

Center the bracket over the hood location and place it flush with the ceiling.
Make sure that the slots of the upper flue bracket point down. Use the
upper flue mounting bracket as a template to mark the location of its
screws. 

Drill both screw holes using a 5/16” drill bit. Insert the included drywall
anchors into the drilled holes (one per hole).

Secure the upper flue bracket to the wall using 2 no. 8 x 1¼” flat head
mounting screws. Make sure that the bracket is thight against the wall.

C

L

HD0247

M

OUNTING BRACKET

FLUSH WITH CEILING

C

ENTER OF

INSTALLATION

C

EILING

Install a wood wall framing between 2 wall studs over the installation location. This framing will 
support hood mounting bracket. 
NOTE:

The framing (shaded part in illustration at right) must be flush with the wall studs surface. 
Refer to figure at right.

HH0099

W

ALL

S

TUDS

S

URFACE

C

L

HD0260A

4

3”

W

ALL

S

TUDS

H

OOD

M

OUNTING

B

RACKET

W

ALL

F

RAMING

WARNING

!

WARNING

!

Summary of Contents for Jazz VJ70430SS

Page 1: ...LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 10 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv c...

Page 2: ...s turn hood ON when cooking at high heat or when cooking flaming foods i e Cr pes Suzette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to acc...

Page 3: ...it is recommended to wear safety glasses and gloves To reduce the risk of fire use only metal ductwork 6 ROUND DUCT ROOF CAP ROUND ELBOW 24 ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0098A...

Page 4: ...cord exits from the hood see illustration at right Make sure this does not interfere with a mouting bracket fastening area or with the decorative flue where the flue touches the wall 3 WIRING INSTALLA...

Page 5: ...upper flue bracket point down Use the upper flue mounting bracket as a template to mark the location of its screws Drill both screw holes using a 5 16 drill bit Insert the included drywall anchors in...

Page 6: ...vertighten the screws in order to ease the sliding motion of the upper flue HO0106A 2 BRACKET SLOTS UP LOWER FLUE UPPER FLUE HO0105 C B A 1 Place the hood on a table Use a piece of cardboard to avoid...

Page 7: ...hood until it is hung to the bracket Using 2 no 8 x 1 screws secure the lower flue mounting bracket to the wall 5 Slide a 6 steel round duct over the duct collar use metal foild duct tape to seal the...

Page 8: ...ONT D HO0104 UPPER FLUE LOWER FLUE UPPER FLUE MOUNTING BRACKET 8 HD0300 8 Drill both screw holes using a 5 16 drill bit through inner hood mounting holes Insert the included drywall anchors into the d...

Page 9: ...ulb with JC type 12 V 20 W Max G 4 base halogen bulb 4 Reinstall the light bulb cover with the light rim by gently squeeze both light ring tabs A and insert ring B in light assembly until secure Make...

Page 10: ...steel or stainless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the...

Page 11: ...9 Not illustrated 3 1 2 4 5 6 7 REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good working condition you must use Venmar Ventilation Inc genuine replacement parts o...

Page 12: ...ice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit remo...

Reviews: