2. C

ONTROLS

 

(

CONT

D

)

 2.2 

B

OOT

 S

EQUENCE

The unit boot sequence is similar to a personal computer boot sequence. Each time 
the unit is plugged after being unplugged, or after a power failure, the unit will perform 
a 30-second booting sequence before starting to operate. During the booting sequence, 
the integrated control LED will light GREEN or AMBER for 5 seconds, and then will shut 
off for 2 seconds. After that, the LED will light RED for the rest of the booting sequence. 
During this RED light phase, the unit is checking and resetting the motorized damper 
position. Once the motorized damper position completely set, the RED light turns off and 
the booting sequence is done. 

NOTE: No command will be taken until the unit is fully booted.

 2.3 

O

PTIONAL

 M

AIN

 

AND

 A

UXILIARY

 C

ONTROLS

For more convenience, these units can also be controlled using an optional main control.
Only one main control can be connected per unit.
NOTES:  1.  The integrated control must be turned OFF to use an optional main control.
 

2. If an optional auxiliary control is used, its activation will override the main 

  

control 

operation.

For more information about your unit controls, refer to the 

Main and auxiliary wall controls 

user guide

 (included with your unit and also available at www.venmar.ca).

5

Summary of Contents for AVS Constructo 1.0 HRV

Page 1: ...eeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA They meet ENERGY STAR requirements only when used in Canada 21785 rev 02 VB0203 AVS C12 ERV Top ports model no...

Page 2: ...OFF for a few hours Do not use your unit during construction or renovation of your house or when sanding drywall This type of dust may damage your system Since the electronic control system of the uni...

Page 3: ...LESHOOTING 8 1 DEFROSTING MODE When the outdoor temperature is below 5 C 23 F heat or energy recovery creates frost in the core To maintain its proper operation the unit is programmed to defrost its c...

Page 4: ...s deux vis pour ouvrir le compartiment lectrique Pour retirer compl tement le d tacher de son fil de r tention int rieur No light OFForremotecontroled Amber light LOW speed Green ligh HIGH speed Blink...

Page 5: ...ing the motorized damper position Once the motorized damper position completely set the RED light turns off and the booting sequence is done NOTE No command will be taken until the unit is fully boote...

Page 6: ...dentify the inner parts of your unit VB0078 HRV core Foam filter brackets Core retainers Core foam filters ERV core Foam filter brackets Core retainers Core foam filters VB0077 3 1 QUARTERLY MAINTENAN...

Page 7: ...ner and a soft brush attachment Once the core reinstalled in the unit always rotate both core retainers to their initial position failure to do so will cause the core to fall out WARNING Slide the cor...

Page 8: ...r installer 8 The LED of the integrated control is blinking GREEN There is a problem with the thermistor The unit is still working but will defrost frequently Contact your installer 9 The LED of the i...

Reviews: