FITTING MAIN LINE TO POWER UNIT

  Run house vacuum line up to the elbow behind the power 

unit. Insert the end of the line in the elbow opening and 
secure house vacuum line by hand tightening the screw 
and nut provided (see illustration below) 

DO NOT GLUE

.

 Assemble exhaust tubing to exhaust outlet on top or top 

side of the unit, according to the power unit model. 

DO NOT 

GLUE

.

NOTE FOR 700VF1 UNIT ONLY

 

 If desired, the 

coupling or elbow 
used to connect 
the exhaust line to 
the top of the unit 
may be secured 
using two 5/8” 
included screws. 
See illustration at 
right. 

NOTE: Using flexible tubing will ease future top cap removal.

  Make sure all tubing connections are air tight.

 The exhaust should not be vented into a wall, ceiling or 

concealed space in the house. It is recommended to vent 
the vacuum exhaust air to the outdoors. Exterior vented 
exhaust line should end using Model V145 wall cap.

  NOTE: 

For optimal indoor air quality, exhausting the 
power unit to the outdoors is recommended but is 
not required, especially for 700VF1 unit which is 
equipped with an exhaust HEPA filter.

Grounding Instructions – This appliance must be grounded. 
If it should malfunction or break down, grounding provides a 
path of least resistance for electric current, to reduce the risk 
of electric shock. This appliance is equipped with a cord having 
an equipment-grounding conductor and grounding plug. The 
plug must be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes and 
ordinances.

WIRING

This appliance is for use on a standard 120 VAC, dedicated 
15-amp branch circuit with a NEMA 5-15R receptacle. Make 
sure that the power unit is connected to an outlet and has a 
grounding attachment plug that looks like the plug shown in 
illustration below. No adapter should be used with this power 
unit.

NOTE:  Inlet leads to be connected to power unit low voltage 
 

 

tabs using crimp connectors (included in parts bag) 

 

 

and low voltage harness.

POWER UNIT INSTALLATION 
(

CONT

'

D

)

GROUNDING 
INSTRUCTIONS

AJ0001

I

NTAKE

 

LINE

S

CREW

 

AND

 

NUT

 

FROM

 

PARTS

 

BAG

INTAKE LINE TYPICAL CONNECTION 

TO POWER UNIT

    WARNING

!

Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. 
Check with a qualified electrician or service person 
if you are in doubt as to whether the outlet is 
properly grounded. Do not modify the plug provided 
with the appliance – if it will not fit the outlet, have 
a proper outlet installed by a qualified electrician.

AJ0003

AE0044

I

NLET

C

RIMP

 

CONNECTORS

 

TO

 

BE

 

CONNECTED

 

IN

 

LOW

 

VOLTAGE

 

TABS

I

NLET

I

NLET

T

O

 

OTHER

 

INLETS

M

ODEL

 V133 (22/2) 

LOW

 

VOLTAGE

 

WIRE

I

NLET

 

LEADS

G

ROUNDED

 

OUTLETS

G

ROUNDING

 

PIN

Summary of Contents for 550VF1

Page 1: ...E FOR RESIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 24009 rev A AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC WWW VENMAR CA 1 877 896...

Page 2: ...not use with damaged cord or plug If appliance is not working as it should if it has been dropped damaged left outdoors or dropped into water return it to a Service Center 12 Keep your work area well...

Page 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Page 4: ...he center line behind the kick plate through the subfloor Locate the reference hole from beneath the subfloor Cut a 4 x 4 access hole on your chosen position along the center line under the kick space...

Page 5: ...k plate Use a 90 sweep elbow fitting to determine a cut mark on the other end of the pipe Then cut the pipe at the mark Slide the low voltage wires into the CanSweep clips as shown to complete the wir...

Page 6: ...ening of the elbow will securely attach onto the spigot on the back of the CanSweep when it is time for connection Slide the CanSweep and low voltage wires into the opening on the baseboard Friction f...

Page 7: ...ove the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the...

Page 8: ...ng bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Page 9: ...ric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet t...

Page 10: ...ove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off eas...

Page 11: ...new one part no S10941416 Be sure to install it with the gasket on top as shown in illustration B at the botton of the page then snap in place the upper part of the top cap If need be reconnect the ex...