User Manual

Read and save these instructions.

VVI, 550 Lemire Blvd., Drummondville, Qc, Canada

J2C 7W9

H

EAT

R

ECOVERY

V

ENTILATORS

MODELS

:

09/2004                   #02053

VB0021

1000 HE
2000 HE 
3000 HE

3055 Compact

HE 1.3
HE 1.8
HE 2.6

5585 Compact

Summary of Contents for 3055 COMPACT

Page 1: ...Read and save these instructions VVI 550 Lemire Blvd Drummondville Qc Canada J2C 7W9 HEAT RECOVERY VENTILATORS MODELS 09 2004 02053 VB0021 1000 HE 2000 HE 3000 HE 3055 Compact HE 1 3 HE 1 8 HE 2 6 55...

Page 2: ...ndence to us at the address indicated on the product registration card included with this manual WARNING Identifies an instruction which if not followed might cause serious personal injuries including...

Page 3: ...2 0 Diagrams of air flows 3 3 0 Description of unit 5 4 0 Operating the Wall Control 7 4 1 Basic and Venta Controls 8 4 2 Electro and Supra Controls 9 4 3 Ultima Control 10 5 0 Maintenance 11 5 1 Reg...

Page 4: ...ree main operations The unit exhausts stale and humid air from the house and replaces it with fresh air from the outside 1 1 Air Exchange 1 2 Heat Recovery During winter the unit recovers the heat con...

Page 5: ...the home and insures the purification of the ambiant air A mechanical filter traps the large dust particles those visible to the eye 1 3 Circulation available with ULTIMA control only 1 2 Heat Recover...

Page 6: ...ESH AIR FROM OUTSIDE FRESH AIR TO BUILDING STALE AIR FROM BUILDING The direction of the air flow is indicated in each of the following diagrams Please note that the stale air never mixes with the fres...

Page 7: ...025 VF0002 during air exchange during circulation and defrost FILTERED AIR TO BUILDING STALE AIR FROM BUILDING FRESH AIR TO BUILDING STALE AIR TO OUTSIDE STALE AIR FROM BUILDING FRESH AIR FROM OUTSIDE...

Page 8: ...the outside The blower wheels are driven by two motors for 2000 HE 3000 HE 1 8 HE 2 6 HE models The other models have just one motor 8 Capacitor is indispensable to proper motor operation 9 Condensat...

Page 9: ...3 4 5 5 6 7 7 8 9 10 11 12 13 14 VL0012 6 1 3 2 6 5 7 9 10 11 12 13 14 VL0003 4 8 MODELS 2000 HE 3000 HE HE 1 8 HE 2 6 MODELS 1000 HE HE 1 3 3055 Compact 5585 Compact 3 0 Description of the Unit cont...

Page 10: ...20 C 4 F 41 F CO NE S U M M E R VC0035 VC0010 1000 HE HE 1 3 HE 1 8 HE 2 6 2000 HE 3585 Compact 3000 HE 5585 Compact BASIC VENTA 20 C 4 F C 41 F CONDENSATI0N CONTROL A A AIR SUPPLY CONTROL L L CONDEN...

Page 11: ...the summer months During this period unless being afflicted with breathing problems using the humidity control is unnecessary Set the slide switch to OFF Do not exchange in day time exchange at night...

Page 12: ...eans you have to clean your filters 2 To turn off the unit activate the push button once again ADJUSTING HUMIDITY CONTROL Setting during the summer months During this period unless being afflicted wit...

Page 13: ...at low speed and 40 min OFF and red indicator is for 20 min exchange at low speed and 40 min of circulation at high speed NOTE When INTERMITTENT signal is flashing this means you have to clean your f...

Page 14: ...ashed every 3 months Use a vacuum cleaner to remove the heaviest portion of accumulated dust Then wash in hot water 4 Regularly check the screen on the exterior intake hood and clean when necessary Al...

Page 15: ...ers heat recovery core and the exterior air intake exhaust hood 2 Cleaning the wheels and the blower blades 3 Cleaning the condensation tray with soapy water make sure that the drain is not clogged 4...

Page 16: ...ir circulation on windows Store wood in a closed room with a dehumidifier or have the room well ventilated with outside air or store the wood outside Do not adjust the thermostat of your heating syste...