mm.
A large amount of slag is formed
Low quality fuel:
- it is recommended to replace the fuel a
suitable one
Burnt igniter
A burnt heater does not have to mean that it will
be cold in our home. The following instruction
explains how to start the burner even when this
important component is damaged. This process
will not require special skills, just a little
dexterity and patience.
After establishing that the heater is burnt, press
the “Start” button and observe the burner
operation stages. This process starts with a blow,
which lasts about 30 seconds, depending on the
settings, followed by the initial feed, i.e. the
external and internal feeders switch on
simultaneously - the internal feeder runs for a
few seconds longer. When observing the burner
operation, remember not to open the boiler
door. After the initial feed, the igniter activation
icon will appear and at this moment kindling
wood, for example, should be put on the pellet.
The burner should start. Remember that when
the set parameters are reached, the burner will
go out, so it is recommended to change the
settings in such a way that it works continuously
until the igniter is replaced.