MA-MR-ATX2-01-03 Manual ATX2 eng rev3
Rev.3 Page 2 of 2
LOW BATT output
Terminal no. 10
This open collector output collects all low battery events from the memorized sirens. When a low battery transmission
arrives from one of the memorized sirens, the output is switched to low level. The display and the
low battery LED DL3
display and memorized the event. This condition persists until the flat batteries of the siren are replaced.
Button P1
This button allows to transmit constantly a radio signal to be memorized on the outdoor sirens.
In this phase, the display shows the letter “t” flashing.
During programming it is used to delete a siren code. During power-on (first start-up) it generates a new 16-bit code.
In this phase it displays horizontal dashes in continuous rotation.
Button P2
This allows to access programming, select the 8 zones to be memorized and to exit programming.
Description of the terminal board
Terminal
no. 1
Positive power supply 13.6
VDC
Terminal
no. 2
Negative power supply
GND
Terminal
no. 3
ON/OFF
input for
negative
signals (0 V equals control panel ARM)
Terminal
no. 4
ON/OFF
input for
positive
signals (12 V equals control panel ARM)
Terminal
no. 5
ALARM
input for
negative
signals
Terminal
no. 6
ALARM
input for
positive
signals
Terminal
no. 7 and no.8 TAMPER
(relay NC 100 mA)
Terminal
no. 9
SUPERVISION
negative
output max
30 mA
Terminal
no. 10
LOW BATTERY
negative
output max
30 m A
Terminal
no. ANT TX
Output for receiving antenna
Terminal
no. GND
Terminal
no. ANT RX
Input for receiving antenna
Technical Features
Nominal operating voltage
= 12 Vdc
Stand-by absorption
= 20 mA
In alarm absorption
= 100 mA
Piezo-electric siren frequency
= da 2600 Hz a 3600 Hz
Transmitting frequency
= 433.92 Mhz with ASK (10mW) modulation
Receiving frequency
= 433.92 Mhz with ASK superheterodyne receiver
Operating temperature
= from +5°C to + 40°C
Via del Lavoro, 10-30030 Salzano (VE) Tel. 041 5740374 – Fax 041 5740388 Web site www.venitem.com E-mail [email protected]
0681