MAINTENANCE 

 

 

 

WARNING

 

 

Before servicing or cleaning unit, switch power off at service panel and lock in access to prevent it being switched on accidentally. 
If the power panel can not be locked, put a prominent warning device, such as a brightly coloured label. 

 

Grease filters 

The grease filters should be cleaned once a month or as needed. To remove grease filter, pull the metal latch down. This will disengage the filter 
hood. Tilt the filter down, then remove. To clean the filters, use a solution of warm water and detergent. Let them dry, then reinstall. The metal 
filters are dishwasher-safe. Clean filters made entirely of metal in the dishwasher using a non-phosphate detergent. Using a detergent containing 
phosphates and local water conditions may cause discoloration of the filters, without affecting their performance. This discoloration is not covered 
under warranty.

 

 
 
 
 

 

 
Hood Cleaning 
Cleaning stainless steel: how to keep his "lustrous appearance" and help prevent corrosion. 
What to do: 
- Wash surfaces regularly with a cloth or a clean cloth soaked in warm water and mild soap or dish detergent. 
- Always clean in the direction of squall lines (direction of the grain). 
- Always rinse well with clear water (2 or 3 times) after cleaning and dry completely. 
- A household cleaner designed for stainless steel can also be used. 
Don'ts: 
- Use steel wool or stainless steel or any other scrapers to remove stubborn dirt. 
- Use any harsh or abrasive cleansers. 
- Allow dirt to accumulate. 
- Allow the plaster dust or any other construction residues reach the hood. Cover the hood while working to ensure no dust hood. 
To avoid when choosing a detergent 
- Any cleaners that contain bleach, because they attack stainless steel. 
- Any product containing chloride, fluoride, iodide, bromide, they quickly deteriorate surfaces. 
-  Any  combustible  products  used  for  cleaning  such  as  acetone,  alcohol,  ether,  benzene,  etc..  These  products  are  highly  explosive  and  should 
never be used near a stove. 

 

 

To replace the bulbs:

 

1.  Gently  push  the  bulb  up  and  turn  in  the  opposite  direction  of  clockwise  to 
disengage the drivers out of their grooves. 

2. Install the new bulb by dragging its drivers in the grooves inside the socket.

  

3. Gently push up and turn in the clockwise until the bulb is in place. 

NOTE: If necessary, use a rubber dishwashing glove to get a better grip of the bulb 
when removing it. 

 

 

 

 

Summary of Contents for VT-ANG30

Page 1: ...T VIT30 VT VIT36 VT ZEN2 VT ZEN30 VT ZEN36 VT ZEN650 VT BAC30 ISALND HOOD VT ANG36IL VT VIT36IL VT ZEN36IL VT ZEN3612IL VT ZEN42IL UNDER CABINET HOOD VT REG30 VT REG30W VT CON30 PRO UNDER CABINET HOOD VT PROC30 VT PROC36 INSERT HOOD VT IN2816 VT IN2812 Range hoods Veneto ...

Page 2: ...e 3 4 Electrical requirements and installation requirements 5 Examples and positioning possibilities for ducts 6 to12 Clearance 13 Necessary Tools 14 Installation Drawings and Dimensions 15 to 28 Maintenance 29 warranty 30 ...

Page 3: ...is important to provide sufficient air for proper combustion of heating equipment and proper evacuation of gases through the chimney pipe to prevent back flow of air Follow the instructions and safety standards of the manufacturers of heating equipment such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engine...

Page 4: ...confined to the area where it was formed Firefighters were called You can fight against the fire with an exit behind you operative MODE 1 Always leave safety grills and filters in place Without the presence of these blowers could catch hair fingers or clothing The manufacturer is not liable if detailed in this manual for installation information maintenance and proper use of the product are not ob...

Page 5: ...d must be plugged directly into a 110 volt wall outlet Before installing the hood 1 To ensure the most efficient ventilation possible install the pipe in a straight line or with the least elbows possible CAUTION The output of the vent pipe should give to the outside 2 Two people are required for installation 3 Supplied hardware can secure the hood to most walls and ceilings consult a qualified ins...

Page 6: ...loss damage or fire caused by non observance of the instructions contained in this manual Ventilation methods The hood is equipped with a vertical transition to remove fumes outside Recommended diameter conduit is 7 for model VT ANG30 VT ANG36 VT VIT30 VT VIT36 VT ZEN30 VT ZEN36 Recommended diameter conduit is 6 for model VT ANG650 VT ZEN650 Models Chimney hood Wall ...

Page 7: ...7 Chimney hood Wall VT BAC30 Positioning options for the hood ducts VT BAC30 Vertical outlet 6 round and rectangular horizontal rear exit 4 1 2 x 9 or 3 1 4 X 10 provides ...

Page 8: ...Exit 4 1 2 x 9 include Exit 3 1 4 x 10 include ...

Page 9: ...9 Island model Hood VT ANG36il VT VIT36il VT ZEN36il VT ZEN3612IL VT ZEN42IL Positioning options for blocks ducts hoods VERTICAL DUCT 7 maximum length pipe is 20 ...

Page 10: ...Under cabinet models VT PROC30 VT PROC36 VERTICAL DUCT 8 maximum length pipe is 20 Positioning options for hood ducts under cabinets ...

Page 11: ...11 Under cabinet models VT REG30 VT REG30W VT CON30 VERTICAL AND HORIZONTAL RECTANGULAR PIPE 3 1 4 X 10 REQUIRED otherwise it will create additional noise maximum length pipe is 15 ...

Page 12: ...Insert Hood models VT IN2816 VT IN2812 Positioning options for blocks ducts hoods maximum length pipe is 20 ...

Page 13: ... pass You can determine for yourself how high you install the hood above the stove Over the hood near the stove it is more effective to capture cooking odours grease and smoke CAUTION INSTALLATION FOR COOKING WITH GAS INSTALL THE HOOD SO THAT THE DISTANCE BETWEEN THE LOWER EDGE OF THE HOOD AND THE HOB IS OF 30 76 2 CM FOR ELECTRIC RANGES DISTANCE BETWEEN THE BOTTOM EDGE OF THE HOOD AND COOKING ARE...

Page 14: ... lines drawn on the bracket with the center lines on the wall Identify the two screw holes on the wall Drill pilot holes 5 16 in the locations shown Place the fastening clips to the wall Tighten wood screws by hand in the attachments to allow hooks to expand Remove the screws Attach the bracket to the wall using the screws and or fasteners Ceiling pipe If the duct vents just above the ceiling Use ...

Page 15: ...15 Installation and dimensions diagram patterns for chimney hood VT ANG30 VT ANG36 VT ANG650 VT VIT30 VT VIT36 VT ZEN30 VT ZEN36 VT ZEN2 VT ZEN650 VT BAC30 ...

Page 16: ...Installation and dimensions diagram patterns for hood s chimney ...

Page 17: ...17 Installation and dimensions diagram patterns for island hoods VT ANG36il VT VIT36il ...

Page 18: ...Installation and dimensions diagram patterns for island hoods VT ZEN36il VT ZEN42 Installation dimensions and patterns for island hoods ceiling pattern for up to 12 VT ZEN3612IL ...

Page 19: ...19 Installation and dimensions diagram patterns for island hoods ...

Page 20: ...Installation and dimensions diagram patterns for hoods VT PROC30 VT PROC36 ...

Page 21: ...21 Installation and dimensions diagram patterns for hoods VT PROC30 VT PROC36 ...

Page 22: ...en the hood is turned on press the K5 button to activate the timer stop time adjust to the desired time delay off timer by pressing increase K2 or K3 decrease button When it reaches 0 the fan stops Activate the normal function of the fan When the hood is a decrease and an off button press the increase K2 or K3 button to change the status quiet speed F1 low speed F2 average speed F3 and high speed ...

Page 23: ...23 Horizontal installation dimensions diagrams for models of hoods VT REG30 VT REG30W VT CON30 ...

Page 24: ...Vertical installation dimensions and patterns diagram for hoods VT REG30 VT REG30W VT CON30 ...

Page 25: ...25 Vertical installation dimensions and patterns diagram for hoods VT IN2816 ...

Page 26: ...Vertical installation dimensions and patterns diagram for hoods VT IN2812 ...

Page 27: ...light K3 K4 Button to decrease and increase button Press these two buttons to adjust the speed when the hood is ON Description orders for model VT IN2816 Turn On Press the speed button Low Medium High switch to select the desired level of power Once button is pressed the previous speed mode will cancel Press the Light button to power on the lights Turn Off Press the Power button to turn off the po...

Page 28: ...fan is switch on Press to decrease the fan speed Press to increase the fan speed To switch on or off the lights Up to 15 minutes timer setting and fully adjustable When you press the timer button the digital display will change to 00 timer model You can Adjust timers model up to 15 minutes by pressing or ...

Page 29: ...ld soap or dish detergent Always clean in the direction of squall lines direction of the grain Always rinse well with clear water 2 or 3 times after cleaning and dry completely A household cleaner designed for stainless steel can also be used Don ts Use steel wool or stainless steel or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Allow the...

Page 30: ... in areas where an authorized service center already exists If in home service is not available in the area the unit will be repaired or replaced at the discretion of Co Fan 2012 Inc the authorized service center nearest you The work of removal and reinstallation of the device are the responsibility of the consumer and can not be charged to Ste Fan 2012 Inc The duration of any implied warranty is ...

Reviews: