VENCO VAX Installation, Operation And Maintanance Manual Download Page 2

 

2018.02 

 

  1 / 10

 

INDEX 

1.

 

INTRODUCTION ..................................................................................................................................... 1

 

2.

 

GENERAL IDENTIFICATION OF DEVICE TYPE and MODEL ............................................................... 2

 

3.

 

TECHNICAL DATA ................................................................................................................................. 2

 

4.

 

TECHNICAL SPECIFICATIONS ............................................................................................................. 3

 

5.

 

INSTALLATION ....................................................................................................................................... 4

 

6.

 

OPERATION ........................................................................................................................................... 7

 

7.

 

HANDLING & STORAGE ........................................................................................................................ 7

 

8.

 

MAINTENANCE ...................................................................................................................................... 7

 

9.

 

FAULT DETECTION ............................................................................................................................... 7

 

10.

 

WARRANTY ........................................................................................................................................ 8

 

11.

 

ANNEX ................................................................................................................................................ 9

 

11.1.

 

Annex-1: Electrical Wiring Diagrams ................................................................................................ 9

 

 

1.  INTRODUCTION 

Before  operating  VENCO  branded  VAX  and  VAX-S  Axial  Type  Fans,  please  examine  carefully  the 

instruction manual and keep it. Do not use devices as a workbench or a storage area. VENCO VAX and VAX-
S  Axial  Type  Fans  can  only  be  operated  in  conditions  of  intended  design  and  technical  specifications.

 

 

 

 

 

 

 

BEFORE OPERATING READ THIS MANUAL and KEEP IT IN REACH OF A SERVICE 
PERSONNEL. 

 

THIS FAN CAN ONLY BE OPERATED IN CONDITIONS OF INTENDED DESIGN AND 
TECHNICAL SPECIFICATIONS. OTHERWISE THE RESPONSIBILITY BELONGS TO 
INSTALLER. 

 

DO NOT USE THIS FAN IN EXPLOSIVE and CORROSIVE ENVIRONMENT. 

 

RESPONSIBILITY OF THE DEFECTS WHICH CAN BE OCCURED AS A RESULT OF 
UNAUTHORIZED  PERSONNEL  INTERVENTION  TO  FAN  or  TO  BE  USED  NON-
ORIGINAL SPARE PARTS BELONGS TO THE INSTALLER. 

Summary of Contents for VAX

Page 1: ...TION MAINTENANCE USER MANUAL AXIAL FANS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MAN SA T RK YE Tel 0090 236 332 5070 Fax 0090 236 332 5030 www venco com tr venco ven...

Page 2: ...t Do not use devices as a workbench or a storage area VENCO VAX and VAX S Axial Type Fans can only be operated in conditions of intended design and technical specifications BEFORE OPERATING READ THIS...

Page 3: ...The Axial fans may not be used in areas in which an explosion capable atmosphere can be found The motor is found combined with the impeller in canals where the air circulation actualized and the air f...

Page 4: ...motors with IP 55 and F class insulation 230 V 1 phaze 50 Hz and 380 V 3 phase 50 Hz Operating temperature between 15 C and 45 C VENCO VAX S Type Axial Fans F300 certificate harmonized with EN12101 3...

Page 5: ...access by unauthorized persons The fan should be installed in a way that makes service and maintenance easy A wiring diagram is applied on the inside of the junction box or separately enclosed Electr...

Page 6: ...nstallation of the NRDO accessory Drawing 5 3 demonstrates horizontal installation of the NRDO accessory to the axial fan When there is no air flow position of the wing must be as shown in the Drawing...

Page 7: ...13 10 12 5 1400 3 5 4 5 11 13 75 1600 4 5 12 15 ALL ELECTRICAL CONNECTIONS SHALL BE DONE ACCORDING TO EN 60204 1 BY TRAINNED AND AUTHORIZED PERSONNEL SWITCH THE ENERGY SUPPLY OFF BEFORE YOU BRING ABO...

Page 8: ...mpressed air Before service maintenance or repairing disconnect the electrical connections and the impeller is stopped The fan must be cleaned when needed at least once per year to maintain the capaci...

Page 9: ...fan is under warranty of our company The maximum repairing period is 30 business days This period starts from the date of notification to us Fan s warranty does not include electrical connection erro...

Page 10: ...2018 02 9 10 11 1 2 4 kW and Above 11 1 3 Under 4 kW with Thermic...