background image

 

   

Connection precautions.

 

 
1. Disconnect the power supply before installation or maintenance of the light. 
2. It is strictly mandatory to connect the earth cable (Yellow / Green) with the ground connection of the installation. 
3. Do not touch the power source when the lamp is in operation. 
4. To avoid damage, electric shock or fire, do not disassemble or replace the lamp (PCB CHIP LED). 
5. To avoid damage, falls, electric shocks or fires, please do not modify or replace the original accessories with others that are not, 
without consulting and being authorized by Venalsol beforehand. 
6. Only qualified personnel can perform the replacement or installation of the luminaire and make sure that it follows the 
instructions in the manual. If the installation is not carried out properly, it can cause falls, electric shocks, fires or other damages. 
7. Disconnect the power supply if smoke or odor comes out, as this could result in a fire or electric shock. 
8. Consult qualified personnel for inspection and maintenance of the lamp 
9. If the wiring of the luminaire itself is damaged, it can only be replaced by Venalsol. 
 

 

   Applicable regulations

 

 

 

 

 

It has passed the tests and verifications necessary to obtain the CE Marking. This product complies with 

the application standards on Low Voltage (LVD) 2014/35 / EU: EN60598-1: 2015, EN60598-2-24: 2013, 

EN60598-2-1: 1989, EN62031: 2008, EN62471: 2008, EN62493: 2010 and Electromagnetic Compatibility 

(EMC) 2014/30 / EU: EN61000-3-2: 2014, EN61000-3-3: 2013, EN61547: 2009, EN55015: 2013. 

 

 

 

This symbol indicates that the product at the end of its useful life should be removed separately from 

other waste, since it is identified as an appliance for electrical use or domestic appliance according to 

Royal Decree 208/2005. Therefore, at the end of the use, you must take charge of delivering the 

product to a selective collection center or to an authorized waste manager. Venalsol is registered in the 

National Registry of Electrical and Electronic Devices with registration number 3493 and is attached to a 

Waste Management System for Electrical and Electronic Devices for products with the category of 

"lighting devices". 

 

LED Venalsol luminaires are respectful with the environment. They do not contain mercury and the 

electronic components used comply with the provisions of the RoHS regulations transposing Royal 

Decree 208/2005. 

 

 

Technical Parameters

 

 

 

 

Product specifications 

60W 

90W 

120W 

150W 

 

Input voltage 

AC100-277V 50/60Hz Clase I (need a ground) 

CRI 

Ra70 

Light Beam Angle 

(40x150)50º, (40x150)50º, 150º, 150x100º, 60x140º, 110x150º 

IP Rating 

IP66 

Dimensions (mm) 

531 x 219 x 460 mm 

Net weight of the luminaire 

7.5 ±0.3kg 

 

Power factor 

>0.90 

Useful life 

≥50000Hrs (LM70@35

°C) 

Operating temperature 

-30 ~ +50°C 

Operating humidity 

15% ~ 90%RH 

Storage temperature 

-40 ~ +70°C 

 

Installation Instructions 

 

A.

 

Dimensions and installation of the luminaire on pole (adjustable angle) 

Dimensions (mm) 

 

 

 

 
 

 

 

 

 

 

            

 

 

 

 

 

 

B. Inspect inside the luminaire 

 

 

      

 

 

 

 

                

 

 

 

 

 

Wiring diagram 

 

 

 

 

Brown 

 

Marrón  

Yellow/Green       

 

Blue 

 

Azul  

 Dim+ 

 Dim- 

   

 

  

 

 

 

 

 

 