Connection precautions.
1. Disconnect the power supply before installation or maintenance of the light.
2. It is strictly mandatory to connect the earth cable (Yellow / Green) with the ground connection of the installation.
3. Do not touch the power source when the lamp is in operation.
4. To avoid damage, electric shock or fire, do not disassemble or replace the lamp (PCB CHIP LED).
5. To avoid damage, falls, electric shocks or fires, please do not modify or replace the original accessories with others that are not,
without consulting and being authorized by Venalsol beforehand.
6. Only qualified personnel can perform the replacement or installation of the luminaire and make sure that it follows the
instructions in the manual. If the installation is not carried out properly, it can cause falls, electric shocks, fires or other damages.
7. Disconnect the power supply if smoke or odor comes out, as this could result in a fire or electric shock.
8. Consult qualified personnel for inspection and maintenance of the lamp
9. If the wiring of the luminaire itself is damaged, it can only be replaced by Venalsol.
Applicable regulations
It has passed the tests and verifications necessary to obtain the CE Marking. This product complies with
the application standards on Low Voltage (LVD) 2014/35 / EU: EN60598-1: 2015, EN60598-2-24: 2013,
EN60598-2-1: 1989, EN62031: 2008, EN62471: 2008, EN62493: 2010 and Electromagnetic Compatibility
(EMC) 2014/30 / EU: EN61000-3-2: 2014, EN61000-3-3: 2013, EN61547: 2009, EN55015: 2013.
This symbol indicates that the product at the end of its useful life should be removed separately from
other waste, since it is identified as an appliance for electrical use or domestic appliance according to
Royal Decree 208/2005. Therefore, at the end of the use, you must take charge of delivering the
product to a selective collection center or to an authorized waste manager. Venalsol is registered in the
National Registry of Electrical and Electronic Devices with registration number 3493 and is attached to a
Waste Management System for Electrical and Electronic Devices for products with the category of
"lighting devices".
LED Venalsol luminaires are respectful with the environment. They do not contain mercury and the
electronic components used comply with the provisions of the RoHS regulations transposing Royal
Decree 208/2005.
Technical Parameters
Product specifications
60W
90W
120W
150W
Input voltage
AC100-277V 50/60Hz Clase I (need a ground)
CRI
Ra70
Light Beam Angle
(40x150)50º, (40x150)50º, 150º, 150x100º, 60x140º, 110x150º
IP Rating
IP66
Dimensions (mm)
531 x 219 x 460 mm
Net weight of the luminaire
7.5 ±0.3kg
Power factor
>0.90
Useful life
≥50000Hrs (LM70@35
°C)
Operating temperature
-30 ~ +50°C
Operating humidity
15% ~ 90%RH
Storage temperature
-40 ~ +70°C
Installation Instructions
A.
Dimensions and installation of the luminaire on pole (adjustable angle)
Dimensions (mm)
B. Inspect inside the luminaire
Wiring diagram
Brown
Marrón
Yellow/Green
Blue
Azul
Dim+