PTZ-BOX 5.0 User manual, document edition: 13
64
Configuration
After device installation and connection according to manual, it is necessary to configure device
measurement system
parameters. In order to ensure correct operation it’s recommended to
program following parameters:
•
Pulse LF and HF weight
–
Setting of pulse weight must be compatible with description on
name plate of gas meter.
•
Volume at measurement conditions
–
Value of volume counter at measurement conditions
Vm in device should be the same as value of gas meter mechanical counter. Setting of the
counter should be done with meter stopped.
•
Registration period (archival data saving).
•
Time setting
–
Current time should be set in the device.
•
Transmission parameters
•
Gas parameters programming
–
Gas parameters should be compatible with gas supplier
analysis.
•
Zeroing range of pressure input p2
–
If device has measurement pressure input with range up
to 1.0 bar, it is necessary to do zeroing.
•
Activate accounts of users, which will have access to device configuration