Set the temperature T0 (off mode)
To set the temperature value T0 use the following command:
T0
[value]
[value] is a numeric value from 1.0 to 50.0 or DISABLED
For example:
T0 4.5 : set the temperature T0 to 4.5 ° C
T0 7 : set the temperature T0 to 7 ° C
T0 DISABLED: deactivates the antifreeze temperature.
Note: by deactivating the antifreeze temperature, when the off mode is set, no
minimum temperature is guaranteed with the consequent risk of system freezing.
Set the temperature Tm (manual mode)
To set the temperature value Tm use the following command:
Tm
[value]
[value] is a numeric value from 2.0 to 50.0
For example:
Tm 18.5: set the temperature Tm to 18.5 ° C
Set temperatures T1, T2, T3 (automatic mode)
To set the temperature values T1, T2 and T3 use the following commands:
T1
[value]
T2
[value]
T3
[value]
[value] is a numeric value from 2.0 to 50.0
Note: the condition T1<=T2<=T3 must be respected
For example:
T1 6.0: set the temperature T1 to 6 ° C
T3 21.8: sets the temperature T3 to 21.8 ° C