OPERATION 

User Manual
RADIOFREQUENCY ELECTRONIC TOUCH SCREEN THERMOSTATS

 

Read carefully all the instructions

DIMENSIONS

DEVICE DESCRIPTION

INSTALLATION

2

Advanced programming

Reset

Setpoint modification

Depleted batteries signal

Error messages

Thalos RF

  

Ambient temperature display

  

Active off-mode indicator

  

Boiler activation indicator (heating mode) 

  

Air conditioner activation indicator (cooling mode)

  

Programming keys

USE, CLEANING AND MAINTENANCE

Press the keys with your fingers. The use of sharp objects may cause damage to
the device. 

To clean the display use a soft, slightly damp and lint-free cloth, without using 
excessive force.

Attention: the keys are active only if the device is hooked to the base

Switch off

Normal operation

Note: in heating mode (winter), if the Thalos RF is off, it regulates the antifreeze 

Toff

 

temperature in order to prevent freezing of the system.

Toff

 can have values from 1 to 10° C or be excluded; in this case any minimum 

temperature is guaranteed.

Replace the batteries as soon as 

possible! Dispose of the 
batteries in the appropriate 
recycling containers

Occurs in case of probe failure.
In this case the Thalos RF activates the receiver for 10 
minutes every 4 hours (if the antifreeze temperature 

Toff

 is 

active)

Occurs for the following values of measured tempera-
ture:
t < 0°C
t >50°C

Unhook and re-hook the thermostat from the base. Press the keys for at least 3 seconds during the flashing.

The advanced programming menu is divided into two parts: programming of operating parameters (

PR

) and test of the radiofrequency transmission (

RF

). 

To access it, press simultaneously the keys   and   for at least 3 seconds until 

PR

 appears. At this point choose which menu to access with the keys   or  . 

You will enter the selected menu after 3 seconds without pressing any key.

Modification of the desired temperature (setpoint), 

 to increase    to decrease

Normal operation
heating on (

 

 

)

press

or

3 sec.

3 sec.

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

Thalos RF

19.8

19.9

...

Thalos RF

Thalos RF

Default values

Heating setpoint 

21°C

Cooling setpoint 

25°C

Minimum settable setpoint - 

L0

2°C

Maximum settable setpoint - 

Xi

35°C

Operating mode 

 (heating)

Antifreeze temperature

6°C

Regulation type

On /Off

Differential

0.3°C

Password

- - - (desabled)

Pr

 (parameters programming) 

rF

 (RF connection tes)

3 sec.

3 sec.

Note:  the passage from a menu to the next one occurs after 

3 seconds without keys pressures.

Vemer S.p.A.

I - 32032 Feltre (BL) • Via Camp Lonc, 16

Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: [email protected]  -  web site: www.vemer.it 

V3IS00715-020

 

Mod.

 THALOS RF

Thalos RF is an electronic touch screen thermostat to regulate the ambient 
temperature both in heating and in cooling to control a remote actuator through 
radiofrequency signal.
Powered by two batteries of AAA type, Thalos Rf doesn’t need any wiring. 
This allows to install the thermostat anywhere inside your room, without any 
intervention of masonry.
The wide touch screen display with backlighting on by pressing a key allows a 
clear view even in the dark. 

Code  

Model  

Description

VE480000

 

Thalos RF Bianco 

Radiofrequency thermostat white color

VE481800

 

Thalos RF Nero 

Radiofrequency thermostat black color

SAFETY WARNINGS

 

 During product installation and operation it is necessary to observe the 
following instructions:

1)    The device must be installed by a qualified person, in strict compliance with the 

connection diagrams. 

2)   Do not power the device if any part of it is damaged
3)    The device must be installed and activated in compliance with current electric 

system standards

4)    Do not use the device for purposes different from the one specified.
5)    In case of malfunction do not perform repairs and contact immediately the 

technical support.

6)    The device can be used in environments with category of measurement III and 

pollution degree 2. 

TECHNICAL CHARACTERISTICS

•   Power supply: 2 alkaline batteries from 1.5V ( AAA type)
•   Battery life: about 1 year
•   Wall-mounting installation or to cover the 503 box
•   Summer (cooling) / winter (heating) / off (with antifreeze) operating mode
•   Regulation type:
 

- on/off with settable differential (0.1 ÷ 1°C)

 

- P8 proportional with 0.8°C band (-0.3 ÷ +0.5°C) and period 8 minutes

 

- P15 proportional with 1.5°C band (-0.7 ÷ +0.8°C) and period 15 minutes

 

-  tP proportional by opening modulation (only if associated with valves for 

radiators)

•   Measurement precision: ±0.5°C
•   Measurement temperature resolution: 0.1°C
•   Settable setpoint range: 2°C ÷ 35°C 
•   Operating temperature: 0°C ÷ +50°C
•   Storage temperature: -10°C ÷ +65°C
•   Operating humidity: 10% ÷ 90% non condensing
•   Touch screen display with backlighting on with a key touch
•   Password protected lock keypad
•   Communication with the actuator through a radiofrequency signal 433.92 MHz
•   Maximum distance between thermostat and actuator: 50 m in free field
•   Protection degree: IP40

• Association between Thalos RF and remote actuator

Because the Thalos RF and a remote actuator can communicate correctly, it’s 
necessary to perform a procedure called “self-learning”, during which the remote 
actuator recognizes and stores the identity of Thalos RF.

To perform the self-learning proceed as follows:

1.   Activate the channel configuration of the remote actuator (see the 

instructions). The actuator remains in configuration mode for a pre-set time, 
within which it must receive the configuration string from Thalos RF. 

2.   Insert the batteries in the Thalos RF, respecting the polarity indicated on the 

device (to access the batteries compartment it’s 
necessary to unhook the thermostat from the base 
by pressing the tab at the bottom of the device).  
After about 3 seconds the Thalos RF initiates the 
configuration procedure (indicated by 

[NF

 on the 

display) followed by a short test procedure (indicated 
by 

TST

 on the display) where Thalos RF sends the 

sequence on-off-on-off to the actuator. 

3.   Upon receipt of the configuration string, the remote actuator is configured 

and resumes the normal operation while the Thalos RF displays the ambient 
temperature (the programming keys will be active only after you have hooked 
the thermostat at the base).

• Indications for placement

The Thalos RF is designed for wall-mounting installation or to cover the 503 box. 

1

1

2

Fix the base on the wall 
using the screws supplied. 

Attach the thermostat to the base, at first 
mating teeth first placed on the upper side.

Place the thermostat at a height at about 1.5 m above the floor, away
from direct sunlight, away from doors, windows, heat sources, locations
with excess or total lack of aeration.
The actuator is usually placed near the boiler to pilot.

Attention: the maximum distance between Thalos RF and remote actuator is about 
50 m in free field. This value is reduced if there are obstacles in the middle (for 
example, reinforced concrete walls).

During normal operation the Thalos RF displays the value of the measured temperature and the possible activation command to the remote actuator is indicated by the 
symbol

 

 

(heating mode) or by the symbol

 

 

(cooling mode).

 REFERENCE STANDARDS

Compliance with Community Directives:
2014/53/EU (RED) - 2014/30/EU (EMCD
is declared with reference to the following harmonized standards:
• ETSI EN 300 220-1 • ETSI EN 300 220-2  
• ETSI EN 301 489-1 • ETSI EN 301 489-3

Minimum settable setpoint - 

L0

It’s the minimum value settable as setpoint.
Settable values: 2 ÷ 35°C

Maximum settable setpoint - 

KI

It’s the maximum value settable as setpoint.
Settable values: 

L0

 ÷ 35°C

Operating mode - 

E-I

 if connected to the boiler (heating)
 if connected to a cooling system

Anifreeze temperature - Toff

Minimum temperature maintained with Thalos RF off 
(see box «Switch off»).
Settable values: 1 ÷ 10 °C or --- (excluded function)

Regulation type - 

REG

 

- (only in heating)

0

  

= on/off with settable differential

P8

   =  proportional with band 0.8°C and period 8 minutes

P15

  = proportional with band 1.5°C and period 15 minutes

tP

   =  (to be used only if associated with valves for radiators) allows the valve 

to work by opening modulation, i.e. it opens in proportional way to the 
difference between the setpoint and the measured temperature

Differential - 

d0.3

 - (only for on/off regulation)

Differential (or hysteresis) for temperature regulation
Settable values: 0.1 ÷ 1°C

Password for keypad lock - 

PAS

Set a value between 001 and 999 to activate the keypad lock. 
Set 

---

 to disable the lock.

If the keypad lock is active, pressing one key 

LoC

 appears and 

the password is required. If it’s properly inserted the keyboard 
is unlocked for the next 30 seconds.

Note:  if you do not press any key within 10 

seconds the instrument exits the menu 
showing 

END

.

Test -

 

tSt

The test is used to verify the correct 
communication between Thalos RF and 
the actuator and it can last 10 minutes 
the maximum. To activate the test, 
press the key   for at least 3 seconds 
until 

TST

 will stop flashing. During the 

test the commands of on and off are 
sent to the actuator every 10 seconds.
To stop the test, press the key   for at 
least 3 seconds. 

Note: to associate a second remote actuator, activate the configuration of the actuator 
channel and, while this last is in configuration mode, remove the thermostat from the 
base and re-put it (the thermostat starts the configuration procedure to which follows 
the testing procedure).