- 33 -
Manual User Evo.din
English
—
T
= 25.0 °C [77.0 °F] fi eld of variation: 2.0 °C ÷ 37.7 °C [35.6 °F ÷ 99.9 °F]
with the condition:
≤
.
• Temperature regulation:
— ON-OFF (pre-set) with differential of 0.3 °C [0.5 °F].
— proportional with differential at 1 °C (-0.6 +0.4) [1.8 °F (-1.1 +0.7)], base time 10
minutes.
• Clock: weekly.
• Daily resolution: 1 hour.
• Temperature scale measured:
— 0.0 °C ÷ + 37.7 °C [32.0 °F ÷ 99.9 °F].
• Temperature resolution: 0.1°C
• Accuracy: ± 1 °C.
• Measurement update: every 15 seconds.
• Housing: 4 module DIN, gray RAL 7035
• Protection degree: IP20 (IP41 on the front)
• Remote probe (included): wall-mounted. Cable lengh: until 40 m (bipolar cable,
minimum section 1 mm
2
)
• Operating temperature: 0 °C ÷ 50 °C [32.0 °F ÷ 140 °F].
• Storage temperature: -10 °C ÷ 65 °C [20.0 °F ÷ 155 °F].
• Relative humidity: 10% ÷ 90% non condensing
• Terminal:
— 3 x 6 mm
2
block for relay.
— 2 x 6 mm
2
block for power supply
— 2 x 6 mm
2
block for remote probe.
— 2 x 6 mm
2
block for telephone dialler.