USER MANUAL
ANALOG TIME SWITCH WITH TRIPPERS
Read carefully all instructions
The
ARVO-D
,
ARVO-ED
and
ARVO-W
time switches control any electrical installation by means
of daily (Arvo-D/Arvo-ED) or weekly (Arvo-W) programs. For models ARVO-D and ARVO-W the
cover on the front of the device makes it possible to replace the battery when it is run down.
They are designed for household and similar operation with normal pollution levels.
SAFETY WARNINGS
1) The device must be installed and activated by qualified personnel, following the
connection diagrams provided in this manual scrupulously
2) After installation, it must be made impossible to access the terminals without
specific tools
3) Before accessing the connection terminals, verify that the leads are not live
4) Do not connect or power the device if any part of it is damaged
5) The device must be installed and activated in compliance with current electric
systems standards
6) Do not use the device for purposes other than those indicated.
Code
Model
Description
VP882500
ARVO-D
Daily analog time switch with power reserve
VP882510
ARVO-D
Daily analog time switch with power reserve - 12V
VE785500
ARVO-ED
Daily analog time switch without power reserve
VP883300
ARVO-W
Weekly analog time switch with power reserve
TECHNICAL CHARACTERISTICS
• Power supply:
- 230 V AC 50/60Hz (codes VP882500, VE785500, VP883300)
- 12 V DC ±20% (code VP882510)
• Power consumption:
- 0,5 W (codes VP882500, VP883300)
- 0,5 W, 20 mA (code VP882510)
• Switching capability: 16 (4) A 250 V~
• Operating accuracy: ± 1 second/day at 23°C
• Type of dial:
- ARVO-D/ ARVO-ED: 96 pins
- ARVO-W: 84 pins
• Minimum time of functioning:
- ARVO-D/ ARVO-ED: 15 minutes
- ARVO-W: 2 hours
• Switching accuracy:
- ARVO-D/ ARVO-ED: ± 5 minutes
- ARVO-W: ± 30 minutes
• Manual control by 3 positions selector:
0
- Permanent disconnected
A
- Automatic operation
I
- Permanent connected
• Power reserve: 150 hours (NiMH rechargeable battery – replacing)
only on
ARVO-D
and
ARVO-W
• Operating temperature: -10 °C ÷ +50 °C
• Protection class: II
• Protection category: IP20
• 2,5 DIN modules container
PROGRAM
• Lift the transparent cover
• Move all the setting pins towards the interior of the sphere (contact 3-1 remains closed)
• Move the setting pins corresponding to the desired switch on times outwards, in which contact
3-1 remains closed. Each pin corresponds to 15 minutes of functioning for Arvo-D/Arvo-ED
and 2 hours for Arvo-W
• The number of pins outwards determines the time of functioning
• Rotate the minute hand clockwise until the index and hands indicate the current time
• Close the transparent cover
• Power the device
• Manual mode: 3 positions are available with the selector.
BATTERY REPLACEMENT
• To replace the battery (only on
ARVO-D
and
ARVO-W
):
- disconnect the power supply
- remove the battery holder
- replace the battery
- connect the power supply
• Use V80H batteries only.
• Throw away the run down batteries in compliance
with current regulations on the disposal of armful waste.
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/EU
(LVD)
2014/30/EU
(EMCD)
is declared in reference to the harmonized standard:
• EN 60730-2-7
DIMENSIONS
CONNECTION DIAGRAMS
BATTERY REPLACEMENT
ISCOM048-1910
DESCRIPTION
Battery cover
Index
Programming dial
Manual selector
Incandescent
3000 W
Fluorescent
1200 VA
Low voltage halogen
2000 VA
Halogen (230 V~)
3000 W
Low consumption lamp (CFL
1000 VA
Low consumption lamp (CFL
900 VA
Led
200 VA
Mod.
ARVO-D
Mod.
ARVO-ED
Mod.
ARVO-W