VEMCO – ASCENT–AR / AR2 Manual
28 July
2018
12
3.5
Select Logging Options
By default, the temperaure, tilt, noise, and depth statistics are logged (recorded) once an hour in the
ASCENT-AR memory. The time between recordings can be changed in the
Logging Options
window by
selecting a different “Stats Period” for the statistic of interest.
These statistics are calculated from sample values that were taken every 10 minutes and logged. By default
the sample values are not logged to the ASCENT-AR memory because of their potential effect on the
memory levels. The option is available to log every sample and to chose which statistics will be logged. If
you’d like to change what is logged, follow the steps below.
Click the gear shaped icon in the VUE ribbon and select Logging Options to open
the
Logging Options
dialogue box.
STEP 1
STEP 2
Select which samples should be recorded in the log. The
amount and percentage of total log usage per year is listed
at the bottom of the window to give an indication of the
impact your selections make on memory storage. For
example, logging everything uses 196.4 KiB while the
default of only storing the Stats values uses 16.8KiB.
Select OK.
Return to
default settings
Ambient noise in the area can be recorded
and viewed in VUE. This information may be
helpful in comparing deployment locations
and determining if noise may be affecting tag
detections.
1 KiB (kibibyte) = 1024 bytes
(also known as a kilobyte or kB)