Additional Installation, Operating and Maintenance Instructions (Translation)  

 

English 

 

Edition 07.2010                                                                                                                                             VEM-Ident-No. 73753 01en              

 

Water feeding, technical requirements for the cooling water  

The cooling water must have the quality of drinking water. The maximum water pressure is 3.5 bar, and the 
maximum temperature of the entering water must not exceed 35 °C. The following minimum requirements for 
the cooling system have to be observed.  
 

Size 

Flow rate of  

cooling water  

Min. water  

pressure 

Temperature rise  

of cooling water  

 

[l/min] 

[bar] 

[°C] 

225 

10 

0,5 

250 

16 

0,7 

280 

18 

1,0 

315 

18 

1,5 

355 

20 

2,0 

10 

 
The water inlet and outlet are situated on N-side of the housing. Use suitable sealants for the joints. 
 

 

 

Size 225 to 280  

 

 

 

Size 315/355 

 
 
The water supply must be secured during operation of the motor.  

 

Operation without cooling water is not admissible. 

 
 
In addition there is an air relief plug with 3/8 ” thread on N-end of the motor and a water drain plug with 3/8 “ 
thread at the lowest point for motors of size 225 to 280. When the cooling system is filled, the air relief plug 
must be opened. The motor must be filled with cooling water, until the water exits from the air relief hole. The 
filling procedure must be done carefully to make sure that no air remains inside the cooling circuit. Then the 
air relief hole must be closed. Again an appropriate sealant must be used. Check that the joints are water-
proof.  
To empty the motor, take off the plugs for air relief and water drain. After complete drainage the plugs must 
be tightened again. If the cooling system is filled again, check that all plugs are water-proof. 
 

Auxiliary devices 
Additional thermal motor protection 

For monitoring the stator winding temperature it is possible to have thermo couples installed in the motor 
(PTC thermistors, KTY or PT100). For their connection suitable auxiliary clamps for auxiliary circuits are 
available in the main terminal box or in additional terminal boxes. The connection is done according to the 
attached connection diagram.  

 
Anti-condensation heating 

The heating power and the input supply voltage are indicated on the name plate of the motor. For their con-
nection either in the main terminal box or in the auxiliary terminal boxes suitable clamps for auxiliary circuits 
are provided. The connection is done according to the attached connection diagram. The anti-condensation 
heating has to be switched on only after disconnection of the motor. It shall not be switched on while the 
motor is in operation.  

Summary of Contents for K21B Series

Page 1: ...ee Phase Asynchronous Motors with squirrel cage rotor for low voltage applications Translation Type series K21B K23B WE1B W21B W41B Motors that comply with the Regulation 2005 32 EC and the order No 6...

Page 2: ...by the supplier Symbols In this manual two symbols will be used that indicate important passages Security and warranty advices possible damage to persons included Warning against electric voltage dan...

Page 3: ...nd shield 25 45 75 170 275 Bearing cover 5 8 15 20 20 Terminal box 4 7 5 12 5 20 Engineering design Up to size 280 the housing of the motor is manufactured as grey cast iron housing with cast in cooli...

Page 4: ...freezing of the cooling water inside the motor must be prevented For that purpose the cooling water can be drained off or an anti freeze must be added to the cooling water respectively before storage...

Page 5: ...xits from the air relief hole The filling procedure must be done carefully to make sure that no air remains inside the cooling circuit Then the air relief hole must be closed Again an appropriate seal...

Page 6: ...ero potential For design versions with condensate drain hole please observe that the drain plug screw has to be lubricated with a suitable sealant for example Epple 28 before relocking Spare parts Exc...

Page 7: ...dard design surface cooled motors are adapted for both rotational directions The connections U1 V1 W1 at phases L1 L2 L3 in alphabetical or natural order result always in clock wise rotation The sense...

Page 8: ...Additional Installation Operating and Maintenance Instructions Translation English Edition 07 2010 VEM Ident No 73753 01en 8...

Page 9: ...nance Instructions Translation English Edition 07 2010 VEM Ident No 73753 01en 9 VEM motors GmbH Carl Friedrich Gau Stra e 1 D 38855 Wernigerode phone 49 0 39 43 68 0 fax 49 0 39 43 68 21 20 email mot...

Reviews: