Veltron VHOE-120 User Manual Download Page 5

- 5 -

STOVES & CHIMNEYS

NOTICE FOR SAFETY

CAUTION

In case of storing this heater, be sure that you store 

it in the dry places indoor instead of hot and humid 
environment.

(Otherwise, it gets rusty or goes into trouble)

If the supply cord is damaged, it must be replaced by 
the manufacturer or its service agent or simi-larly 
qualifi ed person in order to avoid a hazard.

Do not put this heater on unstable surface of ground 
such as inclined or bumpy.

(The heater may not work properly.)

Do not put an excessive physical shock to the re-
mote controller, nor disassemble it arbitrarily.

(it arbitrarily.)

You must take out the plug from the outlet, if there 
is a fl ash of lightening or thunder or you don’t use it 
for a long time.

(Otherwise, it is exposed to the danger of electrical 

shock, short circuit or a fi re.)

Call your local after sales service agent in case the 
power cord is damaged.

(Otherwise, it is exposed to the danger of electrical 

shock, short circuit or a fi re.)

Do not shower water to the heater directly, nor use 
benzene, thinner, alcohol for cleaning.

(Otherwise, it is exposed to the danger of electrical 

shock, short circuit or a fi re.)

Do not operate this heater in the place where it gets 
wet by the humid such as bathroom.

(It may cause an electrical short circuit or an electrical 

shock accident)

TIPS BEFORE INSTALLATION ...

1. Make sure the safety in the place where you wish to use this heater.

* The ground surface and surrounding should be plain and non-flammable, and solid.

* You need to have sufficient space surrounding the heater at least 15cm from the wall and the left & right side, at least 1 m distance from the ceiling and the 

front side without any obstacle.

* You need to use exhaust duct in case of operating in small spaces.  It is recommended but not required. Take a look at the drawing.

(Recommended Duct specification: 75mm (Diameter) x 5meter long-aluminum duct) (Be sure there must not be rain drops into the exhaust duct end.) (You 

must ventilate frequently with fresh air by opening window or fan.)

* You must put an extinguisher beside the heater.

* There must not be direct sun light, excessive heat near the heater.

* After you fix the installation, lock the caster for avoiding unexpected movement.

* Do not use this heater near fabric curtain, carpet or plastic or vinyl curtain which may cover the heater in case of falling down by the wind or by any physical 

force, which may cause a fire.

* The heater must not be located immediately below a socket-outlet.

* Positioned so that the plug is accessible.

2. You must use Diesel or kerosene as fuel.

* If you use other fuel, it may cause an excessive soot or trouble of malfunction.

* In case of refueling make sure the heater is turned OFF.

* To be made by the manufacturer or his service agent who should be contacted if there is an oil leakage.

* Regulations concerning the disposal of oil when scrapping the appliance have to be followed.

3. The proper electricity is 220/230V, 50Hz. It will be applied and adjusted as per customer’s request. 

You must supply power as per its requirement only once it is adjusted.

How to install the product

* Install the heater in the flat area. If you install the heater in sloped area, combustion furnace 

may be damaged by the irregular combustion.

* Install the flue tube for the indoor use. If the flue tube passes through the inflammable 

wall, wrap the inside wall more than 3cm with nonflammable insulation.

* Use stainless steel tube (75mm diameter) for the flue tube. Length of tube must be shorter

 than 4m and number of bent must not exceed 2.

* If the bent number of flue tube is more than 2 or when the length of tube is longer than 4m, 

it may cause incomplete combustion.

Summary of Contents for VHOE-120

Page 1: ...on where the user can find easily It is obligatory that the user read Notice for Safety carefully before using and should be aware of this notice whenever using this heater This heater is designed for...

Page 2: ...RE DESCRIPTION FOR MODEL 6 CONTROLLER 6 REMOTE CONTROLLER 7 HOW TO USE 8 10 OPERATION STOP 8 TEMPERATURE CONTROL 9 SELF DIAGNOSIS FOR THE SAFETY DEVICE 10 CLEANING MAINTENANCE 11 DAILY CHECK POINTS AD...

Page 3: ...to turn OFF this heater by taking out the power plug It may cause a malfunction or electrical shock Please turn OFF using RUN STOP button Put a plug into the outlet tightly with Earth only It may cau...

Page 4: ...just after extinguish ing the grill and furnace are hot so do not touch any of those parts Especially pay attention more to keep children away from the hot materials It may cause a burn Do not move or...

Page 5: ...all spaces It is recommended but not required Take a look at the drawing Recommended Duct specification 75mm Diameter x 5meter long aluminum duct Be sure there must not be rain drops into the exhaust...

Page 6: ...sensor Fuse Burner department Circulation Fan Conduction Sensor Fuel Guage Fuel inlet Temperature Sensor Fuel Filter 1 LED DISPLAY It displays the status of temperature time operation and error etc 2...

Page 7: ...OL 1 ON OFF When heater tums ON or OFF you can this button 2 OFF TIMER Every time you press this button heater repeat set up and cancel 3 TIME SELECT BUTTON To select time control mode 4 TEMP SELECT B...

Page 8: ...sired temperature between 0 40 C Time Set the desired time limit between 10 25min 5min per a press Tip In order to be operated the setting temperature should be higher than current temperature After p...

Page 9: ...is less than 1 C than current temp the operation is stop Current temp Setting temp Opeartion 2 C Current temp Setting temp Opearation stop 1 C Tip The current temp is less than 9 C 16 F the dispaly of...

Page 10: ...onnectong the wire E6 Lack of fuel Lack of fuel Refuel Re operation Hi Temperature is above 50 C Check if the tempatature sensor is installed inside Install the sensor outside If the troubles E1 E6 oc...

Page 11: ...the heater for a long time and you want to maintain it in clean status please power off and cool down the heater and pull out the plug as the above picture and clean according to the following instruc...

Page 12: ...e sure CdS is fixed correctly Mark A should be inserted fully CLEAN OF COMPONENTS In case you need to change components please contact us In case repair or exchange of components please contact the se...

Page 13: ...oil If oil is all consumed without remaining in the tank air can be flow into inside electric pump The method to flow out air Operate the heater When the electric pump operated turn on the air outflo...

Page 14: ...erheating prevention Ventilate with fresh air in the room and turn OFF the heater for a while Refer to page 16 Inclination display lamp ON Ground surface is in clined or not plain Replace the heater i...

Page 15: ...se in fuel pump Excessive air in the pump and nozzle Remove the air in the electric pump EXCESSIVE SOOT IS GENERATED Check if the fuel is Diesel or kerosene It may cause less per formance trouble Drai...

Page 16: ...x 800 940 x 320 x 1020 1290 x 320 x 1020 1290 x 320 x 1190 1290 x 320 x 1190 1340 x 350 x 1510 1370 x 400 x 1800 Weight 42 kg 45 kg 60 kg 63 kg 63 kg 90 kg 116 kg Used Heating Heating Heating Heating...

Page 17: ...chasing date If the problem is occurred by the mistake or misuse of the customer we charge a repair cost even if it is within warranty period 2 This warranty card is valid within your country 3 Please...

Reviews: