VTF Digital thermoregulator Fuzzy logic 

F208B0063 

VTF EVO Digital thermoregulator 

F208B0064 
 

General Information / Informazioni Generali / Informations Générales / Información General / 
Allgemeine Hinweise 

 

               Before using the unit, please read the following instruction manual carefully. 

Prima dell’utilizzo dello strumento si raccomanda di leggere attentamente il seguente manuale operativo. 
Avant d’utiliser l’instrument, il est recommandé de lire attentivement le présent manuel d’instructions. 
Antes de utilizar el instrumento, le recomendamos que lea con atención el siguiente manual de funcionamiento. 
Bitte lesen Sie vor Inbetriebnahme des Geräts diese Bedienungsanleitung sorgfältig durch 

 

 

Do not dispose of this equipment as urban waste, in accordance with EEC directive 2002/96/CE. 
Non smaltire l’apparecchiatura come rifiuto urbano, secondo quanto previsto dalla Direttiva 2002/96/CE. 
Ne pas recycler l’appareil comme déchet solide urbain, conformément à la Directive 2002/96/CE. 
No tirar el aparato en los desechos urbanos, como exige la Directiva 2002/96/CE. 
Dieses Gerät unterliegt der Richtlinie 2002/96/EG und darf nicht mit dem normalen Hausmüll entsorgt werden. 

 

This unit must be used for laboratory applications only. 

The manufacturer declines all responsibility for any use of the unit that does not comply with these instructions. 

 

Questo strumento deve essere utilizzato solo per applicazioni di laboratorio. 

La società produttrice declina ogni responsabilità sull’impiego non conforme alle istruzioni degli strumenti. 

 

Cet instrument ne peut être utilisé que pour des applications de laboratoire. 

Le fabriquant décline toute responsabil

ité en cas d’utilisation non conforme aux instructions concernant ces instruments. 

 

Este dispositivo sólo debe utilizarse para aplicaciones de laboratorio. 

El fabricante declina toda responsabilidad por el uso no conforme a las instrucciones de los dispositivos.

  

 

Dieses Gerät darf nur für Laboranwendungen verwendet werden. 

Der Hersteller lehnt jede Haftung für unsachgemäße Verwendung oder Nichtbeachtung dieser Bedienungsanleitung ab. 
 

This unit has been designed and manufactured in compliance with the following standards: 
Lo strumento è stato progettato e costruito in accordo con le seguenti norme: 
L’instrument a été conçu et fabriqué conformément aux normes suivantes: 
El dispositivo se ha sido diseñado y fabricado de acuerdo con las siguientes normas: 
Das Gerät wurde in Übereinstimmung mit folgenden Normen entwickelt und gebaut: 

 

Safety requirements for electrical equipment for measurement, control and for laboratory use 
Prescrizioni di sicurezza per apparecchi elettrici di misura, controllo e per l’utilizzo in laboratorio 
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire 
Prescripciones de seguridad para equipos eléctricos de medición, control y su uso en laboratorio 
Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte 

IEC/EN 61010-1

 

Electrical equipment for laboratory use   

UL 61010-1

 

General requirement - Canadian electrical code  

CAN/CSA-C22.2 No.61010-1

 

Summary of Contents for VTF F208B0063

Page 1: ...solo per applicazioni di laboratorio La societ produttrice declina ogni responsabilit sull impiego non conforme alle istruzioni degli strumenti Cet instrument ne peut tre utilis que pour des applicati...

Page 2: ...ng der Produktqualit t das Recht auf nderung der Ger teeigenschaften vor Safety Regulations Norme di Sicurezza Consignes de Securit Advertencias de Seguridad Sicherheitshinweise The plug disconnects t...

Page 3: ...3...

Page 4: ...I FUNZIONAMENTO 11 3 1 SELEZIONE DELLA TEMPERATURA DI LAVORO 11 3 2 IMPOSTAZIONI TIMER 11 3 3 ALLINEAMENTO DELLA TEMPERATURA 12 3 4 UNIT DI MISURA 12 3 5 SICUREZZE E SEGNALI DI ALLARME 12 4 AVVIO 12 5...

Page 5: ...ACTER STICAS T CNICAS 21 8 ACCESORIOS REFACCIONES 21 1 EINF HRUNG 22 2 MONTAGE UND INSTALLATION 22 2 1 ANSCHLUSS DES PT100 F HLER 22 2 2 INSTALLIEREN DES VTF 22 2 3 KOMBINIEREN DIE VTF MIT MAGNETR HRE...

Page 6: ...integrity of the unit after unpacking The box includes Thermoregulator with power cable for connection to VELP Scientifica AREX AREX DIGITAL PRO AREC X and PW10 Pt100 temperature probe Instruction ma...

Page 7: ...rom the memory every time the instrument is turned off 3 2 Setting the timer From the main window press the key twice to display the working time Working time From 00 00 to 24 59 h min Default value 0...

Page 8: ...ime required To optimize thermoregulation and improve temperature homogeneity stir the sample gently but continuously WARNING When working with set points near the temperature of evaporation check tha...

Page 9: ...e settings intervals C F 10 300 14 572 1 1 VTF EVO Temperature settings intervals C F 10 400 14 752 1 1 Resolution precision C F 0 2 1 0 5 0 9 Working time settings h min From 0 00 to 24 59 Continuous...

Page 10: ...rmoregolatore VTF con cavo di collegamento ad AREX AREX DIGITAL PRO AREC X e PW10 Sonda di temperatura Pt100 Manuale di istruzioni 2 1 Montaggio sonda di temperatura Pt100 Collegare la sonda completa...

Page 11: ...ualizzer la temperatura letta in quel momento dalla sonda immersa nel liquido e termoregoler il liquido alla temperatura impostata NOTA dalla finestra principale tenendo premuto il tasto possibile vis...

Page 12: ...dalla sonda Il ripristino del normale funzionamento avviene spegnendo e riaccendendo lo strumento dopo aver rimosso la causa d allarme Per disattivare AL 2 e AL 3 accendere lo strumento tenendo premut...

Page 13: ...l alimentazione con un panno inumidito con detergenti non infiammabili e non aggressivi 7 Dati tecnici Alimentazione 12 V 9 15 Potenza W 1 2 Dimensioni mm BxHxP 75x145x120 Peso Kg 0 250 Display LCD a...

Page 14: ...de r glage avant arri re 10 Alimentateur 2 Montage et installation Lors de la r ception et apr s avoir enlev l emballage contr ler que l instrument est int gre La fourniture comprend Thermor gulateur...

Page 15: ...des heures aux minutes appuyez sur une fois ou attendez 4 secondes Fig 7 Fig 7 Avec l affichage clignote utiliser et pour s lectionner le temps de travail Si aucune touche n est actionn e pendant 5 s...

Page 16: ...temp rature d vaporation v rifier que la sonde reste immerg dans l chantillon d au moins 10mm travers le cycle de travail L chantillon est soumis l vaporation et pour cette raison il ne peut pas atte...

Page 17: ...10 300 14 572 1 1 VTF EVO R glages temp rature intervalles C F 10 400 14 572 1 1 R solution pr cision C F 0 2 1 0 5 0 9 Temps de travail h min De 0 00 24 59 Mode continu temps de lecture restant Poss...

Page 18: ...dor VTF con cable de conexi n a AREX AREX DIGITAL PRO AREC X y PW10 Sonda Pt100 Manual de instrucciones 2 1 Montaje de la sonda Pt100 Conectar la sonda completa con tapa protectora como se mostra en l...

Page 19: ...predeterminado 0 00 Fig 6 Fig 6 Con y durante la etapa de visualizaci n intermitente es posible programar las horas del tiempo de funcionamiento Para pasar de horas a minutos pulse una vez o espere 4...

Page 20: ...po de funcionamiento Para un mejor control y uniformidad de la temperatura se recomienda una continua y suave agitaci n PRECAUCI N Si se trabaja con un set point pr ximo a la temperatura de evaporaci...

Page 21: ...C F 10 300 14 572 1 1 VTF EVO Temperaturas selec intervalo C F 10 400 14 572 1 1 Resoluci n precisi n C F 0 2 1 0 5 0 9 Tiempo de funcionamiento seleccionable h min De 0 00 a 24 59 Operaci n continua...

Page 22: ...die Temperatur ist au erhalb des zul ssigen Bereichs und oder die Sonde nicht innerhalb eingef gt die Probe 2 Montage und Installation Bitte berpr fen Sie nach dem Auspacken den einwandfreien Zustand...

Page 23: ...g Im Hauptfenster dr cken Sie zweimal um die Arbeitszeit zu anzuzeigen Arbeitszeit von 00 00 bis 24 59 h min Standardwert 0 00 Abb 6 Abb 6 Wenn der Anzeige blinkt verwenden Sie und um die Arbeitszeit...

Page 24: ...Sie die Magnetr hrer Temperatur auf Maximum W hlen Sie die Temperatur und die Arbeitszeit R hren Sie die Probe sanft aber kontinuierlich WARNUNG Beim Arbeiten mit der Temperatur nahe der Verdampfung...

Page 25: ...ierbare Temperatur Intervalle C F 10 300 14 572 1 1 VTF EVO Programmierbare Temp Intervalle C F 10 400 14 572 1 1 Regelung Genauigkeit C F 0 2 1 0 5 0 9 Programmierbare Heizdauer h min Von 0 00 bis 24...

Page 26: ...osotros casa fabricante VELP Scientifica declaramos bajo nuestra responsabilidad que el producto es conforme con las siguientes normas Der Hersteller VELP Scientifica erkl rt unter eigener Verantwortu...

Page 27: ...27...

Page 28: ...zers Digestion Units Distillation Units Solvent Extractors Fiber Analyzers Dietary Fiber Analyzers Oxidation Stability Reactor Consumables Analytical Instruments Analizzatori Elementari Digestori e Mi...

Reviews: