10
B. VENTING:
NOTE: On the VCH8FA119* it is possible to rotate the flue elbow (which is factory installed for vertical
discharge) 90° counter clockwise or clockwise from the vertical position to adapt to various venting
systems.
Notice: Blocked Vent Switch Installation
The blocked vent switch kit must be installed to comply with CAN STD B140.4 where applicable. For
installation instructions see AOPS2687 kit.
CAUTION MUST BE TAKEN NOT TO EXCEED 90° ROTATION (OF THE FLUE
ELBOW) .
ROTATION OF FRONT FLUE ELBOW:
When an installation requires that the flue exit out the left or right side casing, remove the screw securing
the 90 deg. elbow and rotate it 90°. Then, remove knock-out in side casing and extend vent through the
opening.
A trim collar may be ordered to hide the gap around the flue pipe. This trim collar, however, is not
required for operation. Trim collar/gasket part numbers(s) 14132 / 330006 for VCH8FA119*.
The VCH8FA119* may be vented through a standard correctly sized chimney.
The VCH8FA119* may also be horizontally vented through a sidewall. A field model FDVS-67/FOVP-615
side wall vent kits for such applications is available. When installing the sidewall vent kits, outside
combustion air must also be applied to the burner. The following table identifies application order
information.
Table 2: Sidewall vent kits
The Field vent kit is set up with a 6 inch diameter vent pipe for the VCH8FA119* with concentric through-
the-wall vent termination/inlet air vent hood. For Beckett, the combustion air inlet pipe will be reduced to
3” diameter with the Beckett sidewall vent kit.
The side wall vent may be installed either through the knock-out on the right or left side casing of the unit
or vertically out the top opening of the vestibule.
The combustion air inlet can be installed through the either the lower left side casing knockout or the
lower right side casing knockout.
FIELD VENT TERMINATION
KIT
SIDE WALL VENT
ACCESSORIES KIT
COMBUSTION AIR INTAKE
HOOD KIT
(15’ application MAX)
(BURNER SPECIFIC)
(FOR COMBUSTION AIR
APPLICATIONS ONLY)
PART NUMBER
PART NUMBER
PART NUMBER
VH8FA119*
Beckett AFG
AOPS8414
AOPS8394
AOPS8397
BURNER
SIDE WALL VENTING APPLICATION ORDER INFORMATION
Summary of Contents for VCH8FA119P60B
Page 4: ...2...
Page 34: ...32 V Sequence of Operations Flow Chart...
Page 35: ...33...
Page 36: ...34 VI Trouble Shooting Flow Chart...
Page 37: ...35...
Page 38: ...36...
Page 39: ...37...
Page 40: ...38...
Page 42: ...40 Appendix A Replacement Parts for VCH8FA119...
Page 43: ...41...
Page 44: ...42 Appendix B VCH8FA119P60 PSC Wiring Diagram...