background image

 

WSPT1

 Rev. 

01

 

11/03/2010

 

©2009 Velleman

®

 nv

 

 

Press the re-sync button 

[F]

 and wait ±6 minutes. If this doesn’t help, verify whether the 

distance between main station and external sensor is within limits and no interference is present. 

 

Outdoor temperature reading is (much) higher than water temperature. 

 

The external sensor is probably in direct sunlight. Move it to a shady area. 

8.

 

Batteries 

main station 

 

Flip down the foldable stand 

[H]

 to see the battery cover 

[I]

 

 

Remove the battery cover 

[I] 

and insert 2 new identical 1.5V size AAA batteries in accordance with 

the polarity markings inside the battery compartment 

[L]

.

 

 

Close the battery compartment and press the reset button 

[K]

 

 

The indoor temperature is shown and the link status indicator 

[C] 

flashes.

 

external sensor  

 

Open the external sensor by turning the head counter clockwise. Slide the top part out of the housing. 

The battery compartment becomes visible. 

Be careful

 not to touch the electronic circuitry. 

 

Slide the battery compartment cover downward to open it. Insert 2 new identical 1.5V size AA 

batteries in accordance with the polarity markings inside the battery compartment.

 

 

Press the reset button 

[6]

.

 

 

Verify that the rubber seal is in place and in good condition. Place the top back and secure it by 

turning clockwise until you hear a click. 

General

  

 

Do not attempt to recharge non-rechargeable batteries, do not puncture or do not throw batteries in 

fire as they might explode.  

WARNING:  

Handle batteries with care, observe warnings on battery casing. 

Dispose of batteries in accordance with local regulations.  

Keep the batteries away from children.

 

9.

 

Technical specifications 

 

transmission frequency 

433 MHz 

transmission range 

<= 30m (<=100ft) 

measuring range 

-40°C ~ +60°C (-40°F ~ 140°F) ±0.1°C (0.2°F) 

main station 

 

 

LCD size 

41 x 36mm 

power supply 

2x 1.5V AAA (LR03C, incl.) 

dimensions 

72 x 24 x 121mm 

weight ±100g 

external sensor 

 

 

LCD size 

34 x 15mm 

 

storage temperature 

-50°C ~ +70 °C (-58°F ~ 158°F), non-condensing 

 

power supply 

2x 1.5V AA (LR6C, incl.) 

 

dimensions 

Ø100 x 155mm 

 weight 

±205g 

 

Use this device with original accessories only. Velleman nv cannot be held responsible in the 

event of damage or injury resulted from (incorrect) use of this device. For more info 

concerning this product and the latest version of this manual, please visit our website 

www.velleman.eu. The information in this manual is subject to change without prior notice. 

 

© 

COPYRIGHT NOTICE

 

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.  

No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or 
otherwise without the prior written consent of the copyright holder.  