background image

- 3 -

VTDESOL4 – DESOLDERING STATION 

 

1.  Introduction 

 

To all residents of the European Union 
Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm 

the environment. 

Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized 

company for recycling. 

This device should be returned to your distributor or to a local recycling service. 

Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 

Congratulations ! You have selected the ideal solution for all your soldering applications ! We are confident that the 

versatility of this desoldering station and its many special features will satisfy your every need. It is not surprising, 

therefore, that the 

VTDESOL4

 has been one of the electronics industry's favourite desoldering tools for the last 15 

years. We advise you to read this instruction manual carefully. This will enable you to maximise the advantages of 

your new desoldering station. 

 

2.  Special Features 

 

 

ENERGY SAVER : this new feature will automatically be activated whenever the desoldering station remains 

unused for more than fifteen minutes. The "Pause" LED will light up, indicating that the temperature of the tip has 

been reduced by 1/3. This reduces power consumption and extends the life of the tip. 

 

DELAYED SUCTION : This feature allows the pump to continue its suction for 1.5 seconds after the control switch 

has been released. This eliminates the problem of solder clogging the tip. 

 

DIGITAL DISPLAY : This new feature provides the user with accurate temperature readings. Once the installed 

temperature has been reached, the "Set/Read" button can be flipped to the "Read" position. This ensures a 

constant temperature. 

 

CELSIUS/FAHRENHEIT SWITCH : Enables the user to switch from °C to °F and vice versa. 

 

3.  Description 

 

The 

VTDESOL4

 is equipped with a self-contained, temperature-controlled vacuum pump. The vacuum pump is 

maintenance-free. It will not overload with continuous use. The vacuum pump provides a max. suction of 50cm/Hg 

(20"/Hg) and is activated by a push-button switch located on the iron housing. 

 

The 

VTDESOL4

's electronic circuitry enables you to use tip temperatures ranging from 300°C to 450°C (572°F to 

842°F) without having to change the tip or the heating element. The temperature readout can be switched from °C to 

°F or vice versa simply by flipping a switch on the front panel. The temperature is maintained to within ± 3°C (± 6°F) 

of the normal operating temperature through a thermocouple sensor located in the heating element. Consequently, 

even the smallest temperature variations of the tip are monitored and the temperature is rapidly corrected whenever 

necessary. The revolutionary "zero voltage" switching design also protects voltage- and current-sensitive 

components (CMOS devices, etc.) against the damaging currents and transient voltage spikes commonly produced 

by less efficient, mechanically switched desoldering stations. 

 

The heating element heats up very quickly and temperature corrections are executed swiftly The heating element is 

galvanically isolated from the electrical supply by an isolating transformer that prevents the system from using a max. 

tension higher than a (safe) 32VAC. 

Summary of Contents for VTDESOL4

Page 1: ...VTDESOL4 DESOLDERING STATION DESOLDEERSTATION STATION DE DESSOUDAGE USER MANUAL GEBRUIKERSHANDLEIDING NOTICE D EMPLOI...

Page 2: ...roblem of solder clogging the tip DIGITAL DISPLAY This new feature provides the user with accurate temperature readings Once the installed temperature has been reached the Set Read button can be flipp...

Page 3: ...70 F If the temperature is too low the solder will flow too slowly and this may cause the tip to clog you may burn the PCB if the temperature is too high 5 Operating Instructions Verify whether the op...

Page 4: ...or moderate use We recommend cleaning the tip daily if the desoldering station is used on a daily basis Remove excess solder in the tip retaining assembly to prevent the tip from clogging The supplie...

Page 5: ...n and the removed tip has not been replaced After removing the tip you should blow out any oxide dust that may have formed in the tip receptacle Be careful not to get dust in your eyes Replace the tip...

Page 6: ...Be careful not to burn your fingers on the glass solder collector as you slide it free see fig 9 3 Point the collector towards the ground see fig 10 while shaking lightly to free the excess solder Do...

Page 7: ...upwards while pressing and turning the red knob on the butt of the iron 3 Remove the solder collector fig 9 4 Disassemble the solder collector fig 13 14 5 Remove the old filter and replace it with a n...

Page 8: ...accessories only jr international nv cannot be held responsible in the event of damage or injury resulted from incorrect use of this device For more info concerning this product please visit our websi...

Page 9: ...de ingestelde temperatuur is bereikt Zo houdt u de temperatuur constant CELSIUS FAHRENHEIT SCHAKELAAR U kunt nu overschakelen van C naar F en omgekeerd 3 Beschrijving De VTDESOL4 is uitgerust met een...

Page 10: ...eel b Verbind de AC voedingskabel met het stopcontact c Plaats de temperatuurregelaar in de MIN stand d Schakel de netspanning in POWER Het controlelampje gaat branden e Stel de temperatuurregelaar in...

Page 11: ...ruik geen vijlen of schurende materialen om de punt te reinigen Gebruik geen vloeimiddelen die chloride of zuur bevatten Gebruik enkel harshoudende vloeimiddelen Verwijder eventuele oxidelaagjes door...

Page 12: ...en de punt worden samengesmolten 10 Reinigen van verstopte punten OPGELET VERBRAND UW VINGERS NIET TERWIJL U DE PUNT REINIGT 1 Beweeg het reinigingsstiftje heen en weer om de zuigmond van de stift te...

Page 13: ...n Doe dit geregeld om uw desoldeerstation gebruiksklaar te houden 4 Verwijder de stollingsstrip met een tang fig 11 12 5 Reinig de stollingsstrip en de glazen soldeerhouder met de meegeleverde staalbo...

Page 14: ...TDESOL4 2 Gebruik dit toestel enkel met originele accessoires jr international nv is niet aansprakelijk voor schade of kwetsuren bij verkeerd gebruik van dit toestel Voor meer informatie omtrent dit p...

Page 15: ...ton Ainsi toute obstruction de la panne est vit e AFFICHEUR NUMERIQUE Garantit un affichage tr s pr cis de la temp rature Le bouton Set Read doit tre plac dans la position Read d s que la temp rature...

Page 16: ...qui peut mener une obstruction de la panne Une temp rature trop lev e peut endommager le circuit imprim 5 Instructions d op ration V rifiez si la tension de travail de l appareil est identique celle...

Page 17: ...ou 750 F N appuyez pas trop fort sur la panne pendant le dessoudage pour viter tout endommagement Evitez l usage de limes et de mati res abrasives lors du nettoyage de la panne Evitez l usage de fond...

Page 18: ...nt et la panne 10 Nettoyage des pannes obstru es ATTENTION FAITES ATTENTION A NE PAS BRULER VOS DOIGTS EN NETTOYANT LA PANNE 1 Employez le nettoyeur de panne afin de nettoyer le bec de la panne 2 Augm...

Page 19: ...uemment afin de garder votre VT DESOL2 dans un tat d op ration parfait 4 Enlevez la tresse de refroidissement avec une pince fig 11 12 5 Nettoyez la tresse de refroidissement et le r servoir de soudur...

Page 20: ...areil qu avec des accessoires d origine SA jr international ne sera aucunement responsable de dommages ou l sions survenus un usage incorrect de cet appareil Pour plus d information concernant cet art...

Reviews: