4. OUTPUT CAPACITY 
 
The inverter will switch off automatically if the total wattage of the electrical 
appliances exceeds the inverter's output capacity. This will also happen if the 
temperature of the inverter exceeds 55°C due to prolonged use. 
 

 

5. SPECIAL RECOMMENDATIONS 
 
Unplug the AC inverter when not in use and when starting the vehicle's motor. 
 
If the AC inverter makes a beeping sound : switch off your appliance, unplug the 
inverter and restart your vehicle's engine. The beeping sound is simply the low-
battery warning which indicates that the voltage of your battery is getting low. 
Your inverter will shut down automatically if you do not restart your engine and 
continue the use of your inverter. This will leave your vehicle's battery at about 
10.5VDC (21VDC for a 24V inverter), enabling you to start your engine and 
resume operation of the inverter. It also eliminates the possibility of being 
stranded with a dead battery. 
 
To avoid over-discharging the battery, it is advisable to let your engine run for 10 
to 20 minutes after every 2-3 hours of using the AC inverter. This allows your 
vehicle's battery to recharge. 
 
Please remember to connect the "+" wire to the "+" terminal and the "-" wire to the 
"-" terminal if you choose to use an adapter for a direct connection between the 
AC inverter and the battery terminals. IF YOU CONNECT THE WIRES TO 
INCORRECT TERMINALS, THE POLARITY WILL BE REVERSED AND THIS 
WILL DAMAGE THE INVERTER. REVERSED POLARITY WILL INSTANTLY 
VOID YOUR INVERTER'S WARRANTY. 
 
Please remember to disconnect the AC inverter before using the battery charger 
to replenish you battery's voltage. Failure to disconnect the inverter prior to 
connecting a charger may result in an input spike which will damage the inverter. 
CONNECTING THE INVERTER'S INPUT TO A BATTERY CHARGER WILL 
VOID THE WARRANTY AND MAY DAMAGE THE INVERTER. 
 
The battery's voltage must never exceed 15VDC (30VDC for a 24V inverter). 
CONNECTING THE INVERTER TO A DC POWER SOURCE GREATER THAN 
15VDC (30VDC) WILL VOID THE WARRANTY AND MAY DAMAGE THE 
INVERTER. 

Summary of Contents for PI300M

Page 1: ... WARRANTY HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT DIE GARANTIE ERLISCHT UND DER SPANNUNGSWA...

Page 2: ... cable is 2m Please verify if you have chosen the right operating voltage for both input and output 3 OPERATION When connected to an appliance remember to turn on the inverter before turning on the appliance If the buzzer sounds during operation this indicates that the battery voltage is very low and that the inverter will be disconnected in 5 minutes power switch AC output socket voltage indicato...

Page 3: ...stranded with a dead battery To avoid over discharging the battery it is advisable to let your engine run for 10 to 20 minutes after every 2 3 hours of using the AC inverter This allows your vehicle s battery to recharge Please remember to connect the wire to the terminal and the wire to the terminal if you choose to use an adapter for a direct connection between the AC inverter and the battery te...

Page 4: ... not you need this terminal Always use heavy duty yellow and green wiring for this connection In a stationary land based installation the earthing terminal should be connected to a metal earthing stake driven into the ground to a minimum depth of 1 2m One of the battery terminals preferably the negative one should also be connected to the earthing stake if the battery system powering the inverter ...

Page 5: ...e the AC output voltage you must use an AUTHENTIC RMS VOLT METER Using any other type of voltage measuring device will result in an AC voltage reading that is up to 20 to 30 volts lower than the rated value The reading will only be accurate when using an authentic RMS voltmeter 10 VENTILATION IMPORTANT During operation make sure the fan keeps revolving Check the inverter for possible malfunctions ...

Page 6: ...e power at once B disconnect all units C check the connected devices D use the units again as soon as any problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the battery voltage is still very strong This may be caused by excessive temperatures If this happens please proceed as follows A Switch off the ...

Page 7: ...tput wave modified sine wave Efficiency 90 typical No load current 0 65A Input current at 100 load 29 5A for a 12V inverter 16A for a 24V inverter Output current at 100 load 1 266A Battery low alarm shutdown 10 5 0 5VDC for 12V input 21 1VDC for 24V input Overheating protection 55 5 C Dimensions 232 x 104 x 58mm Weight 0 9kg Power switch DC input ON OFF control 15 NOTE All specifications are typic...