PEM7D
Rev. 01
04.06.2010 ©Velleman
nv
5
environmental conditions. Mount the reflector in that
location.
•
When applicable, connect the counter
[6]
(optional, not incl.)
to the output
[5]
using the 10m cable that comes with the
counter (
PEM7D/C
).
5.
Troubleshooting
When problems are encountered, refer to following overview
before contacting your local dealer:
•
Check that the speaker is set to “CHIME” or “ALARM”. “OFF”
= silent.
•
Check that the timer and/or volume are not in the “min.”
position.
•
A red LED indicates proper alignment of the sensor and
reflector. If the LED is not lit, realign sensor and reflector.
Distance must be at least 50cm.
•
Make sure the adapter is firmly connected to the speaker.
•
Make sure the sensor is firmly connected to the input of the
speaker.
6.
Technical specifications
GENERAL
Nominal Detection Range
7m
Supply Voltage
DC 9-15V
Light Source
IR LED
Output NPN
open
collector
Ambient Temperature
-20 to +50°C
SYSTEM
Power Supply
AC to DC adapter 12V (included)
Total Current Consumption < 130mA
Standby Current
25mA
SPEAKER
Supply Voltage
DC 9-15V
Speaker Output
Chime / Off / Alarm selectable through
switch
Speaker Time
± 1 second for chime, 30sec. for alarm
Adjustable Timer 3-30sec.
for
alarm
Adjustable Volume
yes (from 0 to max.)
External Output
NPN output (for external device e.g.
counter)