![Velleman DVM98 Manual Download Page 9](http://html.mh-extra.com/html/velleman/dvm98/dvm98_manual_862193009.webp)
4.6 Resistance
Range
Resolution
Accuracy
200
Ω
0.01
Ω
+ 0.5% of rdg + 10 digits
2k
Ω
0.1
Ω
+ 0.3% of rdg + 10 digits
20k
Ω
1
Ω
+ 0.3% of rdg + 10 digits
200k
Ω
10
Ω
+ 0.3% of rdg + 10 digits
2M
Ω
100
Ω
+ 0.3% of rdg + 10 digits
20M
Ω
1k
Ω
+ 0.5% of rdg + 10 digits
200M
Ω
10k
Ω
+ 5.0% of (rdg - 1000 digits) + 10 digits
Note : On 200M
Ω
range, if short input, display will read 10M
Ω
, this 10M
Ω
should be subtracted from measurement results.
4.7 Frequency
Range
Resolution
Accuracy
20kHz
1Hz
+ 1.5% of rdg + 5 digits
Sensitivity : 200mV rms and input no more 10V rms.
4.8 Capacitance
Range
Resolution
Accuracy
2000pF
0.1pF
20nF
1pF
200nF
10pF
+ 4.0% of rdg + 20 digits
2µF
0.1nF
20µF
1nF
5 Accessories
Test leads
Battery
Operating Manual
Holster
Capacitance Testing Adapter