DVM030
V. 01
–
04/05/2023
10
©Velleman Group nv
1000V
1V
±1%±5
±1.0%±5
9.2
DC & AC CURRENT
Overload protection: fuse F500mA/1000V for mA range
fuse F10A/1000V for 10A range
Frequency range: 40Hz - 1000Hz, Display: TRUE RMS
Range
Resolution
DCA Accuracy
ACA Accuracy
400uA
0.1µA
±1.0%±5
±1.2%±5
4000uA
1µA
±0.8%±5
±1.2%±5
40mA
10µA
±0.8%±5
±1.5%±5
400mA
100µA
±0.8%±5
±1.5%±5
4A
1mA
±1.0%±10
±1.8%±15
10A
10mA
±1.0%±10
±1.8%±15
Overload protection:
F 0.50 A / 1000 V, 6.35 x 32 mm
F 10A / 1000V, 6.35 x 32 mm
9.3
RESISTANCE
Do not conduct resistance measurements on live
circuits
Range
Resolution
Accuracy
4
00Ω
0.1Ω
±0.8%±5
4kΩ
1Ω
±0.8%±5
40kΩ
10Ω
±0.8%±5
400kΩ
100Ω
±0.8%±5
4MΩ
1kΩ
±0.8%±5
40MΩ
10kΩ
±1.2%±15
Overload protection: 250 V DC or AC rms