CU2200_v5
VELLEMAN
6
Example:
ST:001;T:2005/01/27/12:00;V:8.14;A1:2312;A2:2131;K1:1;K2:0;K3:0;K4:1; O:1#
ST
Unit serial number
001
T
Unit internal clock
Date: 27 Jan 2005, time: 12h00
V Operating
voltage
8.14VDC
K1
Alarm channel 1
1
Open
K2
Alarm channel 2
0
Closed
K3
Alarm channel 3
0
Closed
K4
Alarm channel 4
1
Open
O
Relay output 1
1
On
•
Power-Up Message
Whenever the unit is powered up, it will automatically send
RESTART!
to the control centre.
•
System Clock Setup
Command: PWD:XXXX,TIME:AABBCCDDEE%
XXXX Password
AABBCCDDEE Year/month/day/hour/minute
Example:
PWD:1234,TIME:0602031327%
Password: 1234
Clock: 3 Feb 2006, 13h27
•
Phone Number Setup
Command: PWD:XXXX,ALMNU1:ZZZZZZZZZZZ,2:ZZZZZZZZZZZ,3:ZZZZZZZZZZZ,4:ZZZZZZZZZZZ#%
XXXX Password
ZZZZZZZZZZZ Phone
number
Example 1:
PWD:1234,ALMNU1:12345678,2:36925814712,3:159357456,4:951753654#%
Password 1234
When the alarm is triggered, an SMS message is sent to following numbers:
N° 1
12345678
N° 2
36925814712
N° 3
159357456
N° 4
951753654
Example 2:
PWD:1234,ALMNU1:NUL,3:NUL#%
Password 1234
With example 1, following numbers have been cancelled:
N° 1
12345678, not made
N° 2
36925814712, retained
N° 3
159357456, not made
N° 4
951753654, retained