CU2200_v5
VELLEMAN
4
7. SMS Command List (software version 5.0)
Configure the
CU2200
through the command text sent from your mobile phone. Upon reception and processing, the
unit will send a confirmation message to your mobile phone. If the command is incorrect, the unit will reply
SMS
format is error!
a.
System Setup
•
New Password Setup
Command: PWD:XXXX,NEWPWD:YYYY%
XXXX Current
password
YYYY
New password (4 digits)
Example:
PWD:1234,NEWPWD:2222%
Default password: 1234
New password: 2222
•
Manual Health Reporting
Command: PWD:XXXX,STATUS%
[SMS message received]
ST:XXX;T:2005/01/28/13:00;V:XXXX;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:X;K5:X;K6:X;K7:X;K8:X;OUT1:Y;O
UT2:Y;OUT3:Y;#
Example:
ST:002;T:2005/01/28/13:00;V:8.15;A1:0000;A2:0000;K1:X;K2:X;K3:X;K4:1;K5:1;K6:X;K7:X;K8:X;OUT1:1;OUT2:1
;OUT3:1;#
ST
Unit serial number
XXX
ASCII code
T
Unit internal clock
XXXX
Year/month/day/time
V Operating
voltage
XXXX
K1
Alarm channel 1
K1:0 means closed
K1:1 means open
K1 ~ 8
Alarm channel 1 ~ 8
OUT1
Relay output 1
OUT1:0 means open
OUT1:1 means closed
OUT1 ~ 3
Relay output 1 ~ 3 (outputs 2 and 3 are
displayed but not available)
•
Serial Number Setup
Command: PWD:XXXX,SN:YYY%
XXXX Password
YYYY
Serial number (0-999)
Example:
PWD:1234,SN:268%
Password: 1234 (default)
Serial number set into the unit: 268 (default: 000)