CAMTVI10
V. 02 – 18/07/2016
4
©Velleman nv
5.
Installation
General Installation Guidelines
Before proceeding to installing, make sure the mounting surface:
o
is thick enough to securely install an expansion bolt
o
can bear at least 4 times the weight of the dome and mounting bracket.
Choose a location for the camera, keeping following guidelines in mind:
o
do not install the camera in locations where extremely high or low temperatures or excessive
vibrations may occur.
o
avoid mounting the camera near high electro-magnetic fields.
o
do not aim the camera at the sun or other extremely bright objects or reflections (e.g. metal
doors).
5.1
DIP Switch Settings
Before installing the camera, make sure that the protocol, baud rate and address code is fully consistent
with the control system. Refer to the corresponding DIP switch settings below:
ID SW1 – Dome Address Setting
Set the camera’s address with DIP switch SW1. The binary code in the example above reads 00000101
and translates as address 5. Please refer to Appendix I – Address Code Mapping for detailed addresses.
FUN SW2 – Baud Rate Setting and RS-485 Bus Matching Resistance
DIP #
function
1-3
reserved
4-5
baud rate
6-7
reserved
8
resistance
Set the baud rate with DIP switches 4 and 5. Factory default is 2400 bps.
baud rate
9600 bps
4900 bps
2400 bps
1200 bps
Select the matching resistor with DIP switch 8. Set the switch to ON to connect the resistor.