VM206
USER MANUAL
6: Toggle mode
When a Start signal is supplied, the relay contacts transfer immediately to the ON state.
When the Start signal turns ON again, the relay contacts transfer to the OFF state and on the next Start signal
to ON state etc.
Start
Output
Reset
7: Start/Stop timer
When a Start signal is supplied, the relay contacts transfer immediately to the ON state and the set time (t1) begins.
When the set time (t1) has elapsed, the relay contacts transfer to the OFF state.
The timer is reset by applying the Start signal before the set time (t1) has elapsed.
Start
Output
Reset
8: Staircase timer
When a Start signal is supplied, the relay contacts transfer immediately to the ON state and the set time (t1) begins.
When the set time (t1) has elapsed, the relay contacts transfer to the OFF state.
The timer is reactivated by applying the Start signal before the set time (t1) has elapsed.
Start
Output
Reset
fig. 9
fig. 8
fig. 10