Velleman components DCM265 User Manual Download Page 7

DCM265                                                                                                                                                                    GB 

6

 8.3. 

AC 

Voltage 

 

Range Resolution 

Accuracy 

600V 

1V 

±1.5% of rdg + 5 digits 

Input Impedance 

: 10M

 

Max. Input Voltage 

: 600V dc or Vrms ac 

Frequency Response  : 40Hz – 400Hz 
 
 

 8.4. 

Resistance 

 

Range Resolution 

Accuracy 

2k

 

1

 

±1.0% of rdg + 5 digits 

Open-Circuit Voltage  : < 700mV 
Overload Protection  : 250V dc or 250Vrms ac 
 
 

 8.5. 

Audible 

Continuity 

 

Range Continuity 

Beeper 

 

 50

 

Open-Circuit Voltage  : < 700mV 
Overload Protection  : 250V dc or 250Vrms ac 
 
 

9. Operating 

Instructions 

 
Do not exceed the specified limit values in order to avoid overheating and damage. Do not 
measure voltages > 600V to avoid risks of overheating and/or incorrect readings. 
 
 

 9.1. 

AC 

Current 

Measurements 

 
1) Place the rotary switch in the desired A~ position. 
2) Press the trigger to open the jaws. Put one conductor between the jaws and let them close 

again, making sure that the conductor is gripped firmly. 

3) The current value will appear on the display. 
4) Select a higher range if the overrange indication ("1") appears on the display. 
5) The meter may need a few seconds to produce a stable reading when measuring currents in 

the 2A-range. 

 
 

 

9.2. DC Voltage Measurements 

 
1) Select the 600V

 range with the range selector. 

2) Connect the red test lead to the “V

”-jack and the black test lead to the “COM”-jack. 

3) Connect the test leads to the circuit being tested and read the displayed value. 
 
Note : the max. DC input voltage = 600Vdc. Measuring higher voltages may lead to damage or 

electroshocks. 

Summary of Contents for DCM265

Page 1: ...5 DIGITAL CLAMP METER DIGITALE STROOMTANG PINCE AMPEREMETRIQUE DIGITALE STROMZANGE PINZA AMPERIMETRICA DIGITAL User Manual Gebruikershandleiding Manuel d utilisation Bedienungsanleitung Manual del usu...

Page 2: ...ain from using the device if it is not in perfect working order e g damaged housing broken test leads malfunctioning display The device needs 30 seconds to warm up before use Radio interference or pow...

Page 3: ...ve the batteries in case of a prolonged period of inactivity Do not store the device in a hot or moist environment Never ground yourself when performing voltage measurements Do not touch metal pipes o...

Page 4: ...Probe Barriers Keep your fingers behind the probe barriers during measurements Trigger Press the lever to open the jaws The jaws will close again when the lever is released Back light Press the LIGHT...

Page 5: ...DCM265 GB 4...

Page 6: ...size or of the conductor Power Supply 3 x CR2032 battery 3V Battery Low Indication The symbol is displayed Dimensions 194mm L x 72mm W x 35mm H Weight 200g with batteries Measurement Specifications Po...

Page 7: ...t readings 9 1 AC Current Measurements 1 Place the rotary switch in the desired A position 2 Press the trigger to open the jaws Put one conductor between the jaws and let them close again making sure...

Page 8: ...ar on the display if the input is not connected or if the resistance being measured exceeds the max value of the selected range Disconnect the circuit to be tested and make sure that all capacitors ha...

Reviews: