Velleman components DCM265 User Manual Download Page 6

DCM265                                                                                                                                                                    GB 

5

8. Technical 

Specifications 

 
****** General Specifications 
 
Max. voltage between 

600Vrms 

the terminals 
Installation Category 

II 

Pollution Degree 

Operating Temperature 

0 to +40°C, RH < 80% non-condensing 

Storage Temperature 

-10 to +60°C, RH < 70% 

Operating Principle 

Dual-slope integration 

Sampling Rate 

2 readings/sec. 

Display 

3 ½ digit LCD display with max. reading of 1999. Automatic 
function indication and symbol display 

Range Selection 

Manual 

Polarity Indication 

“-“ is automatically displayed to indicate negative polarity 

Overrange Indication 

Only figure “1” is displayed 

Jaw Opening 

28mm (= max. size or Ø of the conductor) 

Power Supply 

3 x CR2032 battery (3V) 

Battery-Low Indication 

The 

-symbol is displayed 

Dimensions 

194mm (L) x 72mm (W) x 35mm (H) 

Weight 

±

 200g (with batteries) 

 
 
****** Measurement Specifications 
 
Position the conductor within the jaws at the intersection of the indicated marks in order to 
obtain max. accuracy. Positioning the conductor differently will result in an additional error of 
1.5%. 
 
Max. accuracy is achieved during a one-year period after calibration. Ideal circumstances 
require an operating temperature of 18 to 28°C (64 to 82°F) and a max. relative humidity of 
80%. 
 
 

 8.1. 

AC 

Current 

 

Range Resolution 

Accuracy 

2A 0.001A 

20A 0.01A 

200A 0.1A 

 

± 1% of r 5 digits 

Frequency Range  : 50Hz to 60Hz 
 
 

 8.2. 

DC 

Voltage 

 

Range Resolution 

Accuracy 

600V 

1V 

±1% of rdg + 5 digits 

Input Impedance 

: 10M

 

Summary of Contents for DCM265

Page 1: ...5 DIGITAL CLAMP METER DIGITALE STROOMTANG PINCE AMPEREMETRIQUE DIGITALE STROMZANGE PINZA AMPERIMETRICA DIGITAL User Manual Gebruikershandleiding Manuel d utilisation Bedienungsanleitung Manual del usu...

Page 2: ...ain from using the device if it is not in perfect working order e g damaged housing broken test leads malfunctioning display The device needs 30 seconds to warm up before use Radio interference or pow...

Page 3: ...ve the batteries in case of a prolonged period of inactivity Do not store the device in a hot or moist environment Never ground yourself when performing voltage measurements Do not touch metal pipes o...

Page 4: ...Probe Barriers Keep your fingers behind the probe barriers during measurements Trigger Press the lever to open the jaws The jaws will close again when the lever is released Back light Press the LIGHT...

Page 5: ...DCM265 GB 4...

Page 6: ...size or of the conductor Power Supply 3 x CR2032 battery 3V Battery Low Indication The symbol is displayed Dimensions 194mm L x 72mm W x 35mm H Weight 200g with batteries Measurement Specifications Po...

Page 7: ...t readings 9 1 AC Current Measurements 1 Place the rotary switch in the desired A position 2 Press the trigger to open the jaws Put one conductor between the jaws and let them close again making sure...

Page 8: ...ar on the display if the input is not connected or if the resistance being measured exceeds the max value of the selected range Disconnect the circuit to be tested and make sure that all capacitors ha...

Reviews: