background image

- 6 - 

3.5. 

Install the Top lintel 

10

 between the posts 

7-8

 at a 

distance  of 

1950mm

 from the 

lower lintel, fasten with the 

screws 

45

 

 

 

 

 

 

 

 

3.6. 

Set four Middle lintels 

11 

between the doorway posts 

7-8

  and side post 

3

, secure 

with the screws 

45

 

 

 

 

 

 

3.7.

 In a door-way, Insert 

carpenters  Square and make 

sure it is 90°. Fasten the Jib-sticks 

12

 with screws 

45 

to posts 

7-8  

 

3.8. 

Fasten the Jib-sticks 

13

  with screws 

45

  to post 

3

 

and top arch. 

 

3.9.

  Fasten  the  Stubborn 

plate for door 

52

  with  screws 

45

  In  the upper left corner of 

the doorway from the inside 

(to prevent the door opening 

inside). 

 

Summary of Contents for MAGNOLIA

Page 1: ...Pipe Covered with High Density UV Polycarbonate Set of product Width 10ft 3m Height 7 1ft 2 15m Length of base 13ft 4m Optional Extension by 6 5ft 2m etc Thank you for cho osing the MAGNOLIA greenhous...

Page 2: ...s The greenhouse should be assembled and installed on the ground according the instruction The buyer should control the assembly quality if it is made by third person Self tapping screws of mount stru...

Page 3: ...2115 with holes for hinge 2 10 Top lintel middle for End face 960 2 11 Middle lintel side for End face 1040 8 12 Jib stick small support 150 4 13 Jib stick middle support 250 4 15 Air gate lintel top...

Page 4: ...tside corner molding 90 1670 8 4 31 Steel Tie band 20x3400 7 3 40 Bolt M6x60mm 42 18 41 Nut M6 42 18 42 Washer M6 56 24 43 Bolt m4x35 mm 40 3 44 Nut M4 40 3 45 Self Tapping screw 4 2 16 for assembling...

Page 5: ...lycarbonate mounting places are indented To comply with the correct geometry the assembly must be made on a flat surface Before assembly sort and decompose the details of the ends doors and intermedia...

Page 6: ...re the Left post 7 to the arc and the right post 8 of the doorway stands with self tapping screws 45 on both sides The distance between posts 7 8 is 910mm 3 3 Connect the Lower lintels 4 4L 4R with li...

Page 7: ...s 7 8 and side post 3 secure with the screws 45 3 7 In a door way Insert carpenters Square and make sure it is 90 Fasten the Jib sticks 12 with screws 45 to posts 7 8 3 8 Fasten the Jib sticks 13 with...

Page 8: ...les must be right and 17 18 with hole for handle must be left Hole for the handle in the top door C should be located below and in the bottom door D from above Insert carpenters Square and make sure i...

Page 9: ...sts 5 2 Next fasten using bolts 40 starter stringers with two intermediate arches E 5 3 Insert 27 X Crimp stringers into 26 starter stringers 5 4 Fasten using bolts 40 the stringers 27 with intermedia...

Page 10: ...self tapping screws 45 so that you get T shaped Anchor legs 5 9 Insert the Anchor legs into the side post from below until it stops fix with two self tapping screws 45 5 10 Install the all Anchor legs...

Page 11: ...utting pattern Annex 1 5 2 Attach part A of Polycarbonate to the end door aligning the bottom edge of the polycarbonate with the bottom lintel of the end Fix part A with self tapping screws 46 through...

Page 12: ...dles from kit 48 into the 12 holes on the door having previously drilled the corresponding holes in the polycarbonate On the reverse side put on the deadbolt and pad fix the handle and pad with self t...

Page 13: ...hers 47 to the side posts and progressive stringers according to the following fastening scheme 6 3 In the same way mount the remaining side sheets of the polycarbonate overlapping with the previous o...

Page 14: ...1 and fix the end of the tape with a self tapping screw 45 to the side post 7 3 Bend the tape in the place where two holes 2 were punched at a distance of 5 cm from each other so that the holes are o...

Page 15: ...self tapping screws 46 19mm on the vertical corners of the frame 6 screws per corner closing the corner joints of polycarbonate sheets 8 2 Mount the remaining corners 29 120 2025 mm over the junction...

Page 16: ...here is no longitudinal distortion of the frame and no displacement of the tie straps from the arches After tamping the ground make sure that the tie straps are not sideways and are located along the...

Page 17: ...situation in which harmful insects crawl into a warm greenhouse with the onset of cold weather and in spring they eat young roots and sprouts If it is not possible to dismantle the sheets it is neces...

Page 18: ...th period after 1 year of full coverage If the repair is determined to be covered under warranty and it is consumer responsibility to send required evidence as pictures and video of damaged or broken...

Page 19: ...moisture from entering the polycarbonate open honeycomb and inside the greenhouse we recommend sealing the joint of polycarbonate sheets along the entire length with a waterproof self adhesive tape de...

Page 20: ...19 Magnolia greenhouse with length 19 5 L 6m 1 base 1 extension Cellular polycarbonate sheet 2100 6000 mm 5 pcs...

Page 21: ...20 Magnolia greenhouse with length of 26 L 8m 1 base 2 extensions Cellular polycarbonate sheet 2100 6000 mm 6 pcs Cellular polycarbonate sheet 2100 2000 mm 1 pc...

Page 22: ...21 Magnolia greenhouse with length of 32 5 L 10m 1 base 3 exten Cellular polycarbonate sheet 2100 6000 mm 7 pcs Cellular polycarbonate sheet 2100 2000 mm 1 pc...

Page 23: ...under proper usage Due to the continuous improvement of the products the manufacturer reserves the right to make changes in the design without prior notice to the consumer The products are not subject...

Reviews: