LOCATION FUNCTION
ENTRY LIMITS & CODE OPTIONS
CODE ENTRY
FACTORY DEFAULT
80
Door forced open
warning & duration
MODE/TIME
0: OFF
1-999: duration of warning in
seconds
8 0 MODE/TIME #
0 (OFF)
81
Propped-up warning
& duration
MODE/TIME
0: OFF
1-999: duration of warning in
seconds
8 1 MODE/TIME #
0 (OFF)
90
Egress mode, delay
warning beep and
alarm
CODE 1: FUNCTION MODE
1: Pulse mode, no warning
2: Pulse mode, with warning beep
3: Pulse mode, with warning beep
& alarm
4: Holding mode, no warning
beep
5: Holding mode, with warning
beep
6: Holding mode, with warning
beep & alarm
CODE 2: DELAY TIME
0: no delay
1-99: delay in seconds between
button press and User Group 1
channel activation
9 0 CODE 1 CODE 2 #
1 (Momentary
mode, no warning
beep, no delay)
Summary of Contents for VMBKP