Control Panel PIN Out
Blue Grey Red Black
5.1
ALARMS AND TROUBLESHOOTING
In case of faults, the following alarms code will appear on the two digits panel integrated in the electrical
box
E1: Ambient temperature: sensor fault
E2: Evaporator coil temperature: sensor fault
E3: Sea water inlet temperature: sensor fault
E4: Condensator temperature: sensor fault
E5: DC internal Blower fault
E7: Comunication error between MCU and room thermostat
LP: Low pressure commutator alarm
HP: High pressure commutator alarm
LT: Evaporator Low temperature on heating mode
In case of E1 – E7 alarms switch Off the unit then Switch On again, if the alarm is still On call an authorized
Uflex – VELAIR Service Center
In Cooling mode the HP alarm reason could be an obstruction in sea water circuit, or a sea water pump
fault. Check the outboard sea water discharge, and in case of poor flow check and clean the sea water
circuit components