Veko Magnus Manual Download Page 5

Coupling 

1

2

4

5

7

8

10

11

1 Disconnect the mains before operating
   the linear lighting system.
2 Example of connected profiles. 

Note

: Profile

   and/or brackets may vary.
3 The flatcable is provided with a curl for extra 
   length for an easy connection. Pull out and ex-
   tend the flatcable.

  

-other.

  

Press profiles together.

  

Tighten Hexagon M5 screws (2x) on both 

  

  

 sides of the profiles.

10 Hook the coupling plate into the profiles.

 

11 Rotate the plate into position.
12 Tighten the slotted M6 bolts (4x).

IP65

6

9

3

12

4 Make sure the male connector is positioned 
   outside the profile, with the backside onto the 
   edge of the connection plate.
5 Align both profiles.
6 Insert the connector through the plate 
   and seals.
7 Make sure connectors firmly 'click' into each-

5/16

Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Coupling

Summary of Contents for Magnus

Page 1: ...oduct families on this page in IP65 specification only In combination with the following linear lighting profiles PWR 05500 PWR 05500 B For further information of applicable profiles see section 3 of...

Page 2: ...nnectors Single unit re placement Sensor MD L re placement Sensor configuration s Pool Emergency LED indicator battery replacement Emergency system info disclaimers General disclaimers Page 3 4 5 6 7...

Page 3: ...easurement E deviding E equally over 2 lineparts 4 In case of Cable duct Sports utility Swimming pool Always use a suspension with at least 3 points IP65 Measurement Recommended length mm Maximum leng...

Page 4: ...wire left KDW hook chain and S hook right 9 Always close the links of both the KDW and S hook 10 Close the link of the S hook 11 Close the link of the KDW hook 12 Example of mounting with threaded en...

Page 5: ...gether 9 Tighten Hexagon M5 screws 2x on both sides of the profiles 10 Hook the coupling plate into the profiles 11 Rotate the plate into position 12 Tighten the slotted M6 bolts 4x IP65 6 9 3 12 4 Ma...

Page 6: ...s Profile Mounting Coupling Note Applicability of bracket may vary depending on the surrounding light line configuration light line application and or IP class IP65 6 16 Manual Veko linear lighting sy...

Page 7: ...erpart on the linear lighting system 8 Insert the connector 9 Connectors should firmly click into eachother 10 Tighten the M5 hexagon bolts on both sides of the light line 11 Hook the coupling plate i...

Page 8: ...ng all electrical con nections are correctly in place and corresponding switch the mains back on IP65 5 8 9 10 5 Place the feed onto the light line aligning the connection plates Tighten the M5 Hexago...

Page 9: ...onto the unit and profile 5 on either side of the unit equally devided 10 Caution Bracket may contain sharp edges 11 Caution Make sure wiring doesn t get stuck between the unit and the profile and is...

Page 10: ...the desired reach and angle of the sensor beam 8 Technical data 9 Sensor reach MD L R round lens MD L Na narrow lens IP65 Technical data Power W 1 5 W 4 W Switched off on Voltage V 220 240 V Length m...

Page 11: ...on or off for a set amount of hours Hold until light responds Hold until light responds 1x Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Fast Blink Slow Blink 3x Flash...

Page 12: ...Check the programmed setting of 3 1 Detection accuracy 3 2 Sensitivity twilight mode 4 Red LED Setting The red LED flashes when detected This can be turn ed off or on It s recommended to turn the red...

Page 13: ...galvanized Important notes After installation inspection off all used products is necessary due to safety regulations This inspection should be on a regular basis and occur at least once a year This i...

Page 14: ...EN 1838 NEN EN IEC 60598 2 22 8 LED color flashing Error condition Cause Solution Green no flashing System OK battery fully charged Off Main off EM mode Rest mode test in progress Green slow 0 25s on...

Page 15: ...inaire are both DALI gear then each can be separately addressed on the same DALI bus This allows common wiring to be used for both normal lighting control and emergency test control During a failure o...

Page 16: ...luminaire a closed system and not an electrical installation at itself The light source of this product is custom made and shall only be replaced by the manufacturer or his service agent At end of lif...

Reviews: