24
Issue V1.0 (2014-01-10)
Figure 5-8
Temp area setting
Configuration instructions
a)
Default with general mode. Preset mode optional
b)
General mode is used in constant place. Preset mode is used for PTZ thermal.
c)
Configure the not more than five regions.
d)
Hold down the left mouse button to set the frame area, right-click the mouse in a regional
context can be deleted region
5.8 Alarm Configuration
Procedure
Step 1
Login Alarm configuration menu
Step 2
Default is full screen, area one, two, three, four, five optional
Step 3
Under normal circumstances, target emissivity is applied with 0.95. When need to
monitor special material, change its value according to its emissivity.
Step 4
Must input the real distance when target is in a distance of within 15 meters. When
distance is more than 15 meters, then keep this value as 15 meters.
Step 5
Enable threshold alarm, set warning thresholds, alarm thresholds
Step 6
Enable Trend alarm, set warning trend values, alarm trend values