Video output 

BNC joint / 1.0

±

0.2Vp-p / 75

Ω 

 

 

2.5 Mechanical

 

 

 

Material 

Stainless 304  

IP level 

IP67 

Pan 

0~360° continuously 

 

Tilt 

-90°~-+30° 

Pan speed 

0.1°/S ~60°/S 

Tilt speed 

0.1°/S ~60°/S 

Unit/ Ship weight 

22Kg / 25Kg 

Mounting 

ceiling 

 

 

2.6 Environmental

 

 

Air pressure 

86

106KPa 

Environment temperature 

-15

~+50

℃ 

Relative humidity 

U

95%RH  (+25

 

 

2.7 Dimension

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

P1. SVEX-Q18 out dimension

 

Summary of Contents for SVEX-Q18

Page 1: ...YHQ18 Explosionproof Camera Manual Book Ver 0 1 Ex Mark II 2 GD Ex d IIC T6 Gb Ta 15 C to 60 C Ex t IIIC T80 C Db Certificate Nemko 11ATEX1022 Veilux User Manual SVEX Q18 Intelligence Camera Set...

Page 2: ...supply power same as nameplate marked before equipment being powered Do not open the pan tilt and enclosure under humid atmosphere otherwise video picture will be influenced because of enclosure good...

Page 3: ...SVEX Q18 Explosion proof Camera Manual Book Ver 0 1 3 Most Suitable Position for Movement Choose the most suitable position when moving the equipment...

Page 4: ...SVEX Q18 Explosion proof Camera Manual Book Ver 0 1 4 Move the camera like this Move the camera like this The camera can be rotated when power off No hammar Do not turn the camera when power on...

Page 5: ...5 YHQ18 Explosionproof Camera Manual Book Ver 0 1 Tighten this screw after the cable is connected Tighten the top panel when camera setting is finished Pay attention to the o ring...

Page 6: ...se 11 3 3 2 Armored Cable Use 11 4 CONNECTION SETTING APPLICATION 13 4 1 System Diagram 13 4 1 1 Connecting Diagram 13 4 1 2 Cable Definition 13 4 1 3 Power and Video Cable Connection 14 4 1 4 Control...

Page 7: ...pparatus for explosive dust Using enclosure and limiting surface temperature for protecting electrical apparatus Chapter 1 Technical requirements this camera owns advantage of small volume light weigh...

Page 8: ...256 Preset position 128 Preset Accuracy 0 1 Electric connection 6 core cable for control Power and video 2 4 Camera Data Brand HITACHI Type VK S858EN Mode PAL Scan Line scan CCD 1 4 SONY CCD Line Scan...

Page 9: ...ical Material Stainless 304 IP level IP67 Pan 0 360 continuously Tilt 90 30 Pan speed 0 1 S 60 S Tilt speed 0 1 S 60 S Unit Ship weight 22Kg 25Kg Mounting ceiling 2 6 Environmental Air pressure 86 106...

Page 10: ...license b The ex marking satisfy environment use c All ex proof and flameproof parts are complete enough for structure d Inside and outside earthlings are ready Stop immediately while there is any unc...

Page 11: ...tighten screw on the base of camera open ex cable screw joint for future use Ex cable Gasket Cable outlet Screw Joint Gasket Cable out P5 b As P6 firstly tight screw joint and then tight ex cable Ex...

Page 12: ...Cover Cable inner layer Sealing Loop Bushing Bushing Joint Steel belt Cable core wire Nut P7 Gasket Taper Volt b as Picture 8 install Ex proof Gland to Armored Cable Armored cable Out Finished Gland...

Page 13: ...protocols Code adapter protocol converter is used for some matrix and RS232 RS485 converter is necessary for some DVR system 4 1 2 Cable Definition While camera leaves factory we supply a Composite Ca...

Page 14: ...as as below please use Control Code Distributor Besides adding a 12Ohm Terminal Resistor between Terminal A and B as T6 Communication Board Jumper JMP2 under off position Camera Camera Camera Camera A...

Page 15: ...ion of the F P After opening the left side panel the dip switch can be seen The customer needs to set the protocol address and baud rate See the below chapter for reference When power is on the camera...

Page 16: ...p Switch K3 K2 K1 Address 0 0 2 If the camera address is No 138 the K1 needs be 8 K2 is 3 and K3 should be 1 see below table Dip Switch K3 K2 K1 Address 1 3 8 4 2 3 Communication Protocol Set Check th...

Page 17: ...HT can change the specification OPEN means OK and it can go into the slave menu as well When the menu item is used it will glitter When system is in scan mode RETURN CLOSE will be shown in the lower l...

Page 18: ...ood connection of Signal cable Check Signal Cable is correct connection Too long communication distance make signal loose Add repeaters to make communication distance longer Signal reflect Short conne...

Page 19: ...selves z Lightning or Act of God If there are additional agreements between Veilux and buyer then agreements shall be strictly done 10 COMPANY COMITTMENT Veilux owns the final design changing and fina...